- 62 -
2. Outdoor unit
No. Part
Operation
Process
Remark
1 General
operation
1) Screw off one fastening bolt from the
electrical box cover, and offload the box
cover;
2) Pull out the connecting cord from the
electrical box;
3) Screw off the five fastening bolts from
the cover board, and offload the cover
board;
Screw the six fastening bolts from the
front panel, and offload the front panel;
4) Screw off the fastening bolts from the
electrical assembly panel;
5) Screw off the eight fastening bolts
and offload the outer frame;
2
Fan motor
1) Do No.”1” firstly;
2) Screw off the fastening nut(Rotate in
clockwise direction);
3) Offload the outdoor fan;
4) Screw off the four fastening bolts
from the electrical motor and offload the
electrical motor;
5) Screw off the two fastening bolts and
offload the bracket;
3 Condenser
1)
Do “1”,”2” firstly;
2) Screw off the fastening bolts at the left
and right sides;
3) weld off the inlet and outlet tubes;
4) Offload the condenser;
Summary of Contents for ASW-H09A4/EAR1-dw
Page 1: ...For model ASW H09A4 EAR1 dw ASW H12B4 EAR1 dw ASW H18B4 EAR1 dw ASW H24B4 EAR1 dw ...
Page 6: ... 4 Remote Controller Instructions ...
Page 7: ... 5 ...
Page 8: ... 6 ...
Page 9: ... 7 ...
Page 10: ... 8 ...
Page 11: ... 9 ...
Page 12: ... 10 ...
Page 13: ... 11 ...
Page 14: ... 12 ...
Page 48: ... 46 ...
Page 68: ... 68 Exploded Pictures 1 Indoor unit exploded picture 7K 9K 12K BTU E Series ...
Page 70: ... 70 2 Outdoor unit exploded picture 7K 9K 12K BTU E Series ...
Page 72: ... 72 3 Indoor unit exploded picture 18K 24K BTU E Series ...
Page 74: ... 74 4 Outdoor unit exploded picture 18K 24K BTU E Series ...
Page 76: ......