- 27 -
The sleeping process under heating mode:
Setting temperature
Previous setting falls 2
℃
temperature
Falls another 2
℃
1h 2h 7h
(
end sleeping process
,
turn off
)
(11)Timing control function
①
The longest Timing time is 24 hour and to be counted per minute, single timing
method
,
the timing function will not be cancelled due to the modes changed, and the
timing indication light on after completing the timing setting.
②
Timing power-off
:
The timing power-off function can be set only under the working condition
of the air-conditioner. The timing range is 1min-24h
,
and the air-conditioner turns off
automatically once the time is over.
③
Timing power-on
:
The timing power-on function can be set only under the working condition
of the air-conditioner. The timing range is 1min-24h
,
and the air-conditioner turns on
automatically once reaching the time.
④
The restart and power-off motions happen after completion of the Timing setting will cause
the automatic cancellation of the previous timing and sleeping setting function.
(12)Self-detecting function
Press the Emergency button and electrify the air-conditioner, the self-detecting
process starts after twice short buzz from buzzer:
Start the electric heating, run the indoor fan at a high fan speed, open the air door to
be the maximum
Æ
the digital display and three indicating light on in 1 second
Æ
digital
displays “11”
、
“22”
、
“33”
、
“44” in turn and 1second for each of them
Æ
Run light on 1
second
Æ
Timer light on 1 second
Æ
Sleep light on 1 second
Æ
Each phase of the
stepping motor’s motion in 1 second
Æ
the indoor fan runs for 1 second at low fan
speed and middle fan speed separately
Æ
the compressor’s motion for 1 second
Æ
The
four-way valve’s motion for 1 second
Æ
Outdoor fan’s motion for 1 second
Æ
Negative
generator’s motion for 1 second
Æ
buzzer deliver one short tone
Æ
Electric heating
runs 30 Seconds and stops, then the air conditioner turns into waiting status, the
self-detecting function ends.
(13)Fault indication
When there is faults happen to the air-conditioner, the Timer lights on. The control light panel
will indicate the corresponding fault codes, which are specified as the following:
Summary of Contents for ASW-H09A4/EAR1-dw
Page 1: ...For model ASW H09A4 EAR1 dw ASW H12B4 EAR1 dw ASW H18B4 EAR1 dw ASW H24B4 EAR1 dw ...
Page 6: ... 4 Remote Controller Instructions ...
Page 7: ... 5 ...
Page 8: ... 6 ...
Page 9: ... 7 ...
Page 10: ... 8 ...
Page 11: ... 9 ...
Page 12: ... 10 ...
Page 13: ... 11 ...
Page 14: ... 12 ...
Page 48: ... 46 ...
Page 68: ... 68 Exploded Pictures 1 Indoor unit exploded picture 7K 9K 12K BTU E Series ...
Page 70: ... 70 2 Outdoor unit exploded picture 7K 9K 12K BTU E Series ...
Page 72: ... 72 3 Indoor unit exploded picture 18K 24K BTU E Series ...
Page 74: ... 74 4 Outdoor unit exploded picture 18K 24K BTU E Series ...
Page 76: ......