- 33 -
otherwise with 3 minutes delay;
⑨
Being initially electrified, the compressor doesn’t have the 3 minutes delay protection, the
outdoor fan starts after 2 seconds of the compressor’s start; When TS
>
TA set by the remote
control, the compressor turns off immediately with no need of 3 minutes delay protection;
⑩
When TE
≥
64
℃
and after last for 10seconds, the compressor and the outdoor fan turn off;
If meet the 3 minutes delay condition and TE
≤
62
℃
, the compressor can start normally.
When the air-conditioner is under overheating protection, if the wind speed setting is by hand,
the indoor fan unit will run at the setting wind speed; if the wind speed setting is automatic, the
indoor fan unit runs at the low fan speed.
⑸
Dehumidification mode
①
The four-way valve always turns off when the dehumidification mode is ongoing. The
control range of the temperature is: 16
℃
- 32
℃
.
②
Under the dehumidification mode, after the 3 minutes delay conditions being meet
satisfactorily, the performance of the compressor and the outdoor fan is as following:
a)TA
≥
TS+2
℃,
the compressor and the outdoor fan works continuously, the wind speed
retains the setting wind speed;
b) TS
≤
TA < TS+2
℃,
the compressor and the outdoor fan runs for 10minutes and stops for
6 minutes
,
The indoor fan turns off during the compressor’s 3 minutes stopping period and
keeps on working in breeze mode under other conditions;
c)TA < TS
,
the compressor and the outdoor fan stop working, and the indoor fan start to work
in breeze mode after stopping for 3 minutes
;
Automatic wind-speed control
:
TA - TS
≥
5
℃,
the wind speed is at high wind;
TS +3
℃
≤
TA
<
TS +5
℃,
the wind speed is at middle wind;
TS +2
℃
≤
TA
<
TS +3
℃,
the wind speed is at low wind;
TS
≤
TA
<
TS +2
℃,
the wind speed is at fitful breeze;
TA
<
TS
,
the indoor fan is off during the 3 minutes delay of the compressor, and 3
minutes later, the wind is at breeze speed.
③
The primary electrifying to compressor has no 3 minutes protection delay, the outdoor fan
starts 2 seconds later after the start of the compressor;
④
When the indoor fan runs, the air door can be set as free swing, and the swing condition is
same as the one under cooling mode
;
a)When TE
≤
-2
℃
last for 10seconds and the compressor runs continuously for above
5minutes
,
if turn off the compressor and outdoor fan, the indoor fan runs at the setting wind
speed; If TE
≥
7
℃,
quit from the protection
;
b) When TE
≥
64
℃
last for 10seconds, the compressor and outdoor fan unit turns off. If meet
the 3 minutes delay condition and TE
≤
62
℃
, the compressor can start normally. When the
air-conditioner is under overheating protection, if the wind speed setting is by hand, the indoor
fan unit will run at the setting wind speed; if the wind speed setting is automatic, the indoor fan
unit runs at the low fan speed.
⑤
This mode includes the functions of timing, sleeping, auto-restart (optional), negative ion
(optional), I feel (optional
)
.
⑹
Ventilation mode
Under ventilation mode, the outdoor unit is always off, the indoor fan runs at the setting wind
Summary of Contents for ASW-H09A4/EAR1-dw
Page 1: ...For model ASW H09A4 EAR1 dw ASW H12B4 EAR1 dw ASW H18B4 EAR1 dw ASW H24B4 EAR1 dw ...
Page 6: ... 4 Remote Controller Instructions ...
Page 7: ... 5 ...
Page 8: ... 6 ...
Page 9: ... 7 ...
Page 10: ... 8 ...
Page 11: ... 9 ...
Page 12: ... 10 ...
Page 13: ... 11 ...
Page 14: ... 12 ...
Page 48: ... 46 ...
Page 68: ... 68 Exploded Pictures 1 Indoor unit exploded picture 7K 9K 12K BTU E Series ...
Page 70: ... 70 2 Outdoor unit exploded picture 7K 9K 12K BTU E Series ...
Page 72: ... 72 3 Indoor unit exploded picture 18K 24K BTU E Series ...
Page 74: ... 74 4 Outdoor unit exploded picture 18K 24K BTU E Series ...
Page 76: ......