background image

technical data

2-Way Blow Ceiling Mounted Cassette

FXCQ-MVE9

air conditioning systems

Summary of Contents for FXCQ20MVE9

Page 1: ...technical data 2 Way Blow Ceiling Mounted Cassette FXCQ MVE9 air conditioning systems...

Page 2: ...air conditioning systems technical data 2 Way Blow Ceiling Mounted Cassette FXCQ MVE9...

Page 3: ...ectrical Specifications 50Hz 4 Electrical Specifications 60Hz 4 2 Safety device settings 5 3 Options 6 4 Capacity tables 7 Cooling capacity tables 7 Heating capacity tables 9 5 Dimensional drawing cen...

Page 4: ......

Page 5: ...min 7 9 9 12 12 16 5 26 33 Low m min 5 6 5 6 5 9 9 13 21 25 Fan Motor Model D17K2AA 1 D17K2AB 1 D17K2AB 1 2D17K1A A1 2D17K1A A1 2D17K2A A1VE 3D17K2A A1 3D17K2A B1 Output high W 10 15 15 20 20 30 50 85...

Page 6: ...t terminals is not below or above listed range limits Maximum allowable voltage range variation between phases is 2 MCA MFA MCA 1 25 x FLA MFA is smaller than or equal to 4 x FLA Next lower standard f...

Page 7: ...use 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A __________ 250V 5A Fan motor thermal fuse C 152 2 152 2 152 2 152 2 152 2 __________ __________ __________ __________ Fan motor thermal prot...

Page 8: ...TES 1 Installation box No 7 is necessary for each adaptor marked 2 Up to 2 adaptors can be fixed for each installation box 3 Only one installation box can be installed for each indoor unit FXCQ MVE It...

Page 9: ...1 2 9 2 0 3 0 1 9 37 0 1 9 1 7 2 3 1 9 2 6 2 1 2 8 2 1 2 8 2 1 2 9 2 0 2 9 1 8 39 0 1 9 1 7 2 3 1 9 2 6 2 1 2 7 2 1 2 7 2 1 2 8 1 9 2 9 1 8 42 0 1 9 1 7 2 3 1 9 2 6 2 1 2 6 2 0 2 7 2 0 2 7 1 9 2 8 1 8...

Page 10: ...7 4 4 2 39 0 4 8 3 8 5 7 4 2 6 6 4 7 6 9 4 8 7 0 4 5 7 1 4 3 7 3 4 1 42 0 4 8 3 8 5 7 4 2 6 6 4 6 6 7 4 7 6 8 4 4 7 0 4 2 7 1 4 0 44 0 4 8 3 8 5 7 4 2 6 5 4 6 6 6 4 6 6 7 4 4 6 8 4 1 7 0 4 0 46 0 4 8...

Page 11: ...3 0 2 8 3 0 2 2 3 1 3 1 3 1 3 1 3 0 2 8 5 0 4 1 3 3 3 2 3 2 3 1 3 0 2 8 7 0 6 0 3 4 3 4 3 2 3 1 3 0 2 8 9 0 7 9 3 5 3 4 3 2 3 1 3 0 2 8 11 0 9 8 3 6 3 4 3 2 3 1 3 0 2 8 13 0 11 8 3 6 3 4 3 2 3 1 3 0...

Page 12: ...7 7 7 5 7 0 7 0 6 0 8 4 8 4 8 0 7 7 7 5 7 0 9 0 7 9 8 7 8 5 8 0 7 7 7 5 7 0 11 0 9 8 8 9 8 5 8 0 7 7 7 5 7 0 13 0 11 8 9 0 8 5 8 0 7 7 7 5 7 0 15 0 13 7 9 0 8 5 8 0 7 7 7 5 7 0 80 10 0 19 8 20 0 5 9 5...

Page 13: ...nsion position Branch duct connection BView Require space or more or more or more Decoration panel Brand name plate Note 3 A View Fresh air intake 6 M5 hole Circumference knock hole FXCQ40 50MVE 3D039...

Page 14: ...Require space or more or more or more Decoration panel Brand name plate Note 3 A View Fresh air intake hole Circumference knock hole Suspension bolt Branch duct connection FXCQ80 125MVE 3D039409A NOTE...

Page 15: ...s 13 Indoor Units 2 Way Blow Ceiling Mounted Cassette FXCQ MVE9 5 Dimensional drawing centre of gravity 5 2 Centre of gravity FXCQ MVE 4D034788B MODEL A B FXCQ20 25 32 MVE 20 140 FXCQ40 50MVE 25 FXCQ6...

Page 16: ...g Mounted Cassette FXCQ MVE9 1 6 VRV Systems Indoor Units 14 6 Piping diagram FXCQ MVE 4D034245C Heat exchanger Filter Filter Electronic expansion valve Fan Gas pipe connection port Liquid pipe connec...

Page 17: ...ce Monitor Green S1Q Limit Switch Swing Flap H1P Light Emitting Diode On Red T1R Transformer 220 240V 22V H2P Light Emitting Diode Timer Green K1R K3R Magnetic relay M1F X1M Terminal block Power H3P L...

Page 18: ...ce Monitor Green S1Q Limit Switch Swing Flap H1P Light Emitting Diode On Red T1R Transformer 220 240V 22V H2P Light Emitting Diode Timer Green K1R K3R Magnetic relay M1F X1M Terminal block Power H3P L...

Page 19: ...2 bar Octave band center frequency Hz Approximate threshold hearing for continuous noise FXCQ25 32MVE Scale 220V 220V H L H L A 34 29 36 30 C 40 34 5 42 36 5 1 5m Mic 4D034331 NOTE 1 Over All dB B G N...

Page 20: ...02 bar Octave band center frequency Hz Approximate threshold hearing for continuous noise FXCQ80MVE Scale 220V 220V H L H L A 39 34 41 36 C 45 40 5 47 42 5 1 5m Mic 4D034334 NOTE 1 Over All dB B G N i...

Page 21: ...ithout prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related to the use and or interpretation of this publicat...

Reviews: