background image

Daikin Europe N.V. is approved by LRQA for its
Quality Management System in accordance with
the ISO9001 standard. ISO9001 pertains to
quality assurance regarding design,
development, manufacturing as well as to
services related to the product. 

Daikin units comply with the European
regulations that guarantee the safety of the
product.

Pre

p

a

re

d

 in

 Be

lg

iu

m by La

nno

o  

(w

w

w

.la

nno

op

ri

nt

.b

e

), 

co

mp

any

 w

h

o

se

 co

nc

er

n fo

r

the envir

o

nmont is 

set

 in the 

E

M

A

S a

n

d

 ISO 14001 syste

ms.

 

Re

spo

n

sib

le E

d

ito

r:

 Da

ik

in 

E

u

ro

pe N.

V.

, Za

ndvo

or

des

tra

at

 300,

 B- 8400 Oos

tende

The present publication is drawn up by way of information
only and does not constitute an offer binding upon Daikin
Europe N.V.. Daikin Europe N.V. has compiled the content of
this publication to the best of its knowledge. No express or
implied warranty is given for the completeness, accuracy,
reliability or fitness for particular purpose of its content and the
products and services presented therein. Specifications are
subject to change without prior notice. Daikin Europe N.V.
explicitly rejects any liability for any direct or indirect damage,
in the broadest sense, arising from or related to the use and/or
interpretation of this publication. All content is copyrighted by
Daikin Europe N.V..

VRV

®

 products are not within the scope of the

Eurovent certification programme.

Naamloze Vennootschap
Zandvoordestraat 300
B-8400 Oostende, Belgium
www.daikin.eu
BTW: BE 0412 120 336
RPR Oostende

Daikin’s unique position as a manufacturer
of air conditioning equipment, compressors
and refrigerants has led to its close
involvement in environmental issues. For
several years Daikin has had the intension to
become a leader in the provision of products
that have limited impact on the
environment. This challenge demands the
eco design and development of a wide
range of products and an energy
management system, resulting in energy
conservation and a reduction of waste.

ISO14001 assures an effective environmental
management system in order to help protect
human health and the environment from the
potential impact of our activities, products and
services and to assist in maintaining and
improving the quality of the environment.

Summary of Contents for FXCQ20MVE9

Page 1: ...technical data 2 Way Blow Ceiling Mounted Cassette FXCQ MVE9 air conditioning systems...

Page 2: ...air conditioning systems technical data 2 Way Blow Ceiling Mounted Cassette FXCQ MVE9...

Page 3: ...ectrical Specifications 50Hz 4 Electrical Specifications 60Hz 4 2 Safety device settings 5 3 Options 6 4 Capacity tables 7 Cooling capacity tables 7 Heating capacity tables 9 5 Dimensional drawing cen...

Page 4: ......

Page 5: ...min 7 9 9 12 12 16 5 26 33 Low m min 5 6 5 6 5 9 9 13 21 25 Fan Motor Model D17K2AA 1 D17K2AB 1 D17K2AB 1 2D17K1A A1 2D17K1A A1 2D17K2A A1VE 3D17K2A A1 3D17K2A B1 Output high W 10 15 15 20 20 30 50 85...

Page 6: ...t terminals is not below or above listed range limits Maximum allowable voltage range variation between phases is 2 MCA MFA MCA 1 25 x FLA MFA is smaller than or equal to 4 x FLA Next lower standard f...

Page 7: ...use 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A __________ 250V 5A Fan motor thermal fuse C 152 2 152 2 152 2 152 2 152 2 __________ __________ __________ __________ Fan motor thermal prot...

Page 8: ...TES 1 Installation box No 7 is necessary for each adaptor marked 2 Up to 2 adaptors can be fixed for each installation box 3 Only one installation box can be installed for each indoor unit FXCQ MVE It...

Page 9: ...1 2 9 2 0 3 0 1 9 37 0 1 9 1 7 2 3 1 9 2 6 2 1 2 8 2 1 2 8 2 1 2 9 2 0 2 9 1 8 39 0 1 9 1 7 2 3 1 9 2 6 2 1 2 7 2 1 2 7 2 1 2 8 1 9 2 9 1 8 42 0 1 9 1 7 2 3 1 9 2 6 2 1 2 6 2 0 2 7 2 0 2 7 1 9 2 8 1 8...

Page 10: ...7 4 4 2 39 0 4 8 3 8 5 7 4 2 6 6 4 7 6 9 4 8 7 0 4 5 7 1 4 3 7 3 4 1 42 0 4 8 3 8 5 7 4 2 6 6 4 6 6 7 4 7 6 8 4 4 7 0 4 2 7 1 4 0 44 0 4 8 3 8 5 7 4 2 6 5 4 6 6 6 4 6 6 7 4 4 6 8 4 1 7 0 4 0 46 0 4 8...

Page 11: ...3 0 2 8 3 0 2 2 3 1 3 1 3 1 3 1 3 0 2 8 5 0 4 1 3 3 3 2 3 2 3 1 3 0 2 8 7 0 6 0 3 4 3 4 3 2 3 1 3 0 2 8 9 0 7 9 3 5 3 4 3 2 3 1 3 0 2 8 11 0 9 8 3 6 3 4 3 2 3 1 3 0 2 8 13 0 11 8 3 6 3 4 3 2 3 1 3 0...

Page 12: ...7 7 7 5 7 0 7 0 6 0 8 4 8 4 8 0 7 7 7 5 7 0 9 0 7 9 8 7 8 5 8 0 7 7 7 5 7 0 11 0 9 8 8 9 8 5 8 0 7 7 7 5 7 0 13 0 11 8 9 0 8 5 8 0 7 7 7 5 7 0 15 0 13 7 9 0 8 5 8 0 7 7 7 5 7 0 80 10 0 19 8 20 0 5 9 5...

Page 13: ...nsion position Branch duct connection BView Require space or more or more or more Decoration panel Brand name plate Note 3 A View Fresh air intake 6 M5 hole Circumference knock hole FXCQ40 50MVE 3D039...

Page 14: ...Require space or more or more or more Decoration panel Brand name plate Note 3 A View Fresh air intake hole Circumference knock hole Suspension bolt Branch duct connection FXCQ80 125MVE 3D039409A NOTE...

Page 15: ...s 13 Indoor Units 2 Way Blow Ceiling Mounted Cassette FXCQ MVE9 5 Dimensional drawing centre of gravity 5 2 Centre of gravity FXCQ MVE 4D034788B MODEL A B FXCQ20 25 32 MVE 20 140 FXCQ40 50MVE 25 FXCQ6...

Page 16: ...g Mounted Cassette FXCQ MVE9 1 6 VRV Systems Indoor Units 14 6 Piping diagram FXCQ MVE 4D034245C Heat exchanger Filter Filter Electronic expansion valve Fan Gas pipe connection port Liquid pipe connec...

Page 17: ...ce Monitor Green S1Q Limit Switch Swing Flap H1P Light Emitting Diode On Red T1R Transformer 220 240V 22V H2P Light Emitting Diode Timer Green K1R K3R Magnetic relay M1F X1M Terminal block Power H3P L...

Page 18: ...ce Monitor Green S1Q Limit Switch Swing Flap H1P Light Emitting Diode On Red T1R Transformer 220 240V 22V H2P Light Emitting Diode Timer Green K1R K3R Magnetic relay M1F X1M Terminal block Power H3P L...

Page 19: ...2 bar Octave band center frequency Hz Approximate threshold hearing for continuous noise FXCQ25 32MVE Scale 220V 220V H L H L A 34 29 36 30 C 40 34 5 42 36 5 1 5m Mic 4D034331 NOTE 1 Over All dB B G N...

Page 20: ...02 bar Octave band center frequency Hz Approximate threshold hearing for continuous noise FXCQ80MVE Scale 220V 220V H L H L A 39 34 41 36 C 45 40 5 47 42 5 1 5m Mic 4D034334 NOTE 1 Over All dB B G N i...

Page 21: ...ithout prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related to the use and or interpretation of this publicat...

Reviews: