SNMP ENTERPRISE ATTRIBUTES
7-14
ChromaFlex Chassis – Operation Manual
ATX Confidential & Proprietary
-- Notification: Module
--
notifLaserTemp NOTIFICATION-TYPE
OBJECTS { notifyObjectIndex, notifyObjectValue, notifyAlarmState,
notifyModuleIndex }
STATUS current
DESCRIPTION
“The notification of laser temperature alarm. There are 4 lasers in the
system. The notifyObjectIndex is
used to identify which one. The notifyAlarmState indicates the alarm
state.”
::= { iTCFlexNotification 10 }
notifLaserPower NOTIFICATION-TYPE
OBJECTS { notifyObjectIndex, notifyObjectValue, notifyAlarmState,
notifyModuleIndex }
STATUS current
DESCRIPTION
“The notification of laser output power alarm”
::= { iTCFlexNotification 11 }
notifLaserRf NOTIFICATION-TYPE
OBJECTS { notifyObjectIndex, notifyObjectValue, notifyAlarmState,
notifyModuleIndex }
STATUS current
DESCRIPTION
“The notification of laser RF alarm. There are 4 lasers in the system.
The notifyObjectIndex is
used to identify which one. The notifyAlarmState indicates the alarm
state.”
::= { iTCFlexNotification 12 }
notifPumpPower NOTIFICATION-TYPE
OBJECTS { notifyObjectIndex, notifyObjectValue, notifyAlarmState,
notifyModuleIndex }
STATUS current
DESCRIPTION
“The notification of pump output power alarm. There are 1 pump in the
system. The notifyObjectIndex is
1. The notifyAlarmState indicates the alarm state.”
::= { iTCFlexNotification 13 }
notifOpticalOutputPower NOTIFICATION-TYPE
OBJECTS { notifyObjectIndex, notifyObjectValue, notifyAlarmState,
notifyModuleIndex }
STATUS current
DESCRIPTION
“The notification of laser optical output power alarm. There are 4 lasers
in the system. The notifyObjectIndex is
used to identify which one. The notifyAlarmState indicates the alarm
state.”
CHAPTER 7: