SNMP ENTERPRISE ATTRIBUTES
7-6
ChromaFlex Chassis – Operation Manual
ATX Confidential & Proprietary
“The model name for the module.”
::= { innoTransCFlexModuleEntry 4 }
innoTransCFlexModuleSerial OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“The serial number for the module.”
::= { innoTransCFlexModuleEntry 5 }
innoTransCFlexModuleTemp OBJECT-TYPE
SYNTAX HeTenthCentigrade
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“The module temperature.”
::= { innoTransCFlexModuleEntry 6 }
innoTransCFlexModuleHwVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“The hardware version(s) of the module.”
::= { innoTransCFlexModuleEntry 7 }
innoTransCFlexModuleDisplayName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“The slot module display name in more user friendly format.
For module spans multiple slots, this attribute shows the same display name
on all occupied slots.”
::= { innoTransCFlexModuleEntry 8 }
--
-- Module Laser Table: contains optics attributes.
--
innoTransCFlexModuleAnalogTable OBJECT-TYPE
SYNTAX SEQUENCE OF InnoTransCFlexModuleAnalogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
“This table contains a set of data for laser elements in the module.”
::= { innoTransCFlexEquip 2 }
innoTransCFlexModuleAnalogEntry OBJECT-TYPE
SYNTAX InnoTransCFlexModuleAnalogEntry
CHAPTER 7: