CRAFT LINE INTERFACE (CLI)
4-18
ChromaFlex Chassis – Operation Manual
ATX Confi dential & Proprietary
ChromaFlex [slot-1] >gainoffset 1
0
steps
Modifi cation
: this command supports modifi cation.
Example #1: In this example, the interface #1 of the slot 7 module’s GainOffset is confi gured with offset
+2.
ChromaFlex [slot-7] >GainOffset 1 modify 2
Request
sent
ChromaFlex[slot-7]
>GainOffset
1
+2
steps
NOTE: The response of a modifi cation request may either be “Request sent” or “Successful”; in
either case, the user shall retrieve the value to confi rm the new value. You may need to wait for a
few seconds or retrieve a couple times to acquire the new value.
GainControl:
displays the gain control mode setting.
Example #1: In this example, the module in slot 1 reports its gain control mode.
ChromaFlex
[slot-1]
>gaincontrol
MGC
Modifi cation
: this command supports modifi cation.
Example #1: In this example, the interface #1 of the slot 7 module’s GainControl is confi gured
with MGC mode.
ChromaFlex[slot-7] >GainControl 1 modify MGC
Successful
ChromaFlex[slot-7]
>GainControl
1
MGC
NOTE: The response of a modifi cation request may either be “Request sent” or “Successful”; in
either case, the user shall retrieve the value to confi rm the new value. You may need to wait for a
few seconds or retrieve a couple times to acquire the new value.
FiberLength:
displays the fi ber length setting in km. This option is only available on ITU version.
Example #1: In this example, the module in slot 1 reports its fi ber length setting as 10 dm.
ChromaFlex [slot-1] >FiberLength 1
10
km
Modifi cation
: this command supports modifi cation.