CRAFT LINE INTERFACE (CLI)
4-16
ChromaFlex Chassis – Operation Manual
ATX Confidential & Proprietary
OPinPower:
displays the optical input power reading in dBm.
Example #1: In this example, the module in slot 1 reports its optical input power reading on input #1 (p.s.
primary optical input).
ChromaFlex [slot-1] >OPinPwer 1
+3.0
(dBm)
Mode:
Displays the Optical Input source option.
Example #1: In this example, the module in slot 1 its mode selection reading as Auto.
ChromaFlex [slot-1] >Mode 1
Auto
Switch:
displays the optical switch position.
Example #1: In this example, the module in slot 1 reports its optical switch position as on primary input.
ChromaFlex
[slot-1]
>switch
primary
thresholddBm
: display threshold setting.
Example #1: In this example, the module in slot 1 reports its optical switch threshold as 0 dBm.
ChromaFlex [slot-1] > thresholddBm
+0.0
OPinPowerAlarm:
displays the alarm status of optical input power.
Example #1: In this example, the module in slot 1 reports the alarm status of optical input #1
power as “MajorLoLo” (e.g. Major alarm with power reading below the low low threshold).
ChromaFlex [slot-1] >OPinPowerAlarm 1
MajorLoLo
SwitchAlarm:
displays the alarm status of optical switch. This alarm is raised if switch is in faulty state.
Example #1: In this example, the module in slot 1 reports the alarm status of optical switch as “Normal”
ChromaFlex
[slot-1]
>switchAlarm
Normal
ModuleTempAlarm:
displays the alarm status of module temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as
Normal.
ChromaFlex
[slot-1]
>ModuleTempalarm
Normal