EN | Blast chillers | User and maintenance manual
32
•
'RQRWÁXVKGLUHFWO\WKHLQQHUSDUWVRIWKHEODVWFKLOOHU because the electrical parts could get damaged.
•
Do not use any hard metal tools to remove the ice
.
•
For the cleaning use only warm water (not hot) with no-aggressive detergents, taking care of
drying the wet parts with a soft cloth.
•
Avoid to use products that contain chlorine or diluted solutions, caustic soda, abrasive detergents,
muriatic acid,
vinegar, bleach or other products that might scratch or grind.
•
We recommend to clean the device at least once a month,
when it used for deep-frozen products.
Attention, during the cleaning operations it is recommended to use work gloves.
3.2 CLEANING THE PROBE
7KHPDLQWHQDQFHRIWKHEODVWFKLOOHUPXVWLQFOXGHDWOHDVWRQHGDLO\FOHDQLQJRIWKHWHPSHUDWXUHFRUH
SUREH
It is essential to keep daily clean the blast chiller room probe. All the pro-
cedures must be carried out with the stationary unit removing the tension
from both the refrigerated item and the condensing unit. We recommend
to rinse carefully the probe with clean water and with hygienized solution.
Refer to the same methods and detergents for cleaning named in the pre-
vious paragraph.
3.3 CLEANING THE CONDENSER UNIT
All the cleaning operations must be carried out when the unit is off, taking off the electric tension from
ERWKWKHGHYLFHDQGWKHFRQGHQVLQJXQLW2QO\TXDOLÀHGVWDIIVKDOOFDUU\RXWWKHFOHDQLQJRSHUDWLRQV
For the cleaning and maintenance of the parts made of stainless steel, follow the below recommendations,
FRQVLGHULQJWKDWWKHÀUVWDQGEDVLFUXOHLVWRJXDUDQWHHWKHQRWR[LFLW\DQGWKHPD[LPXPK\JLHQHRIWKHWUHDWHG
SURGXFWV7KHVWDLQOHVVVWHHOKDVDÀQHOD\HURIR[LGHWKDWSUHYHQWVWKHPDNLQJRIUXVW7KHUHDUHGHWHUJHQWVWKDW
can destroy or corrode that layer, originating therefore corrosions.
%HIRUHXVLQJDQ\GHWHUJHQWVLQTXLUHZLWK\RXUIDPLO\VXSSOLHUDERXWQHXWUDOSURGXFWVZLWKRXWFKORULQHLQRUGHU
WRDYRLGFRUURVLRQVRIWKHVWHHO,QFDVHRIVFUDWFKHVRQWKHVXUIDFHLWLVQHFHVVDU\WRVPRRWKLWZLWKWKHÀQHVW
stainless steel wool or with abrasive cloth made of sinewy synthetic material.
For the cleaning of the stainless steel it is recommended not to use steel wool and do not leave them on it
because little ferrous deposits might remain on the surface and therefore it could cause the making of rust and
compromise the hygiene conditions.
In order to have always a good function of the condensing unit it is necessary to carry out pe-
riodically the condenser cleaning. This cleaning depends mostly on the environment where the
condensing unit is installed.
,WLVDGYLVDEOHWRXVHDQDLUÁXVKEORZLQJIURPWKHLQVLGHWRWKHRXWVLGHRIWKHXQLW,ILWZDVQRWSRVVLEOHXVH
a long bristle brush on the external of the condenser. Be careful not to damage the circuit of the cooling
ÁXLG7KHEXLOWLQFRQGHQVLQJXQLWLVSODFHGLQWKHORZHUVLGHRIWKHEODVWFKLOOHU'RQRWXVHZDWHUVSODVKHV
Attention, during the cleaning operations it is recommended to use work gloves.
ATTENTION
The operations of ordinary and extraordinary maintenance are described on the chapter “7
MAINTANANCE - GARBAGE MANAGEMENT - DISPOSAL OF MATERIALS” Pag. 43.