7.5 REQUESTING SPARE PARTS
After verifying the problem with a specialized technician, When requesting spare parts, after please say clearly :
•
Model of the item
•
Serial number of the item
•
Motivation of the request of support
•
Quantity of the spare part
Possibly, enclose also a picture of the part to be ordered.
8 MESSAGES OF ERROR AND SOLUTIONS
MESSAGE
BREAKDOWN
MALFUNCTION
ERROR
SOLUTIONS
Pr
Ensure that all the cables
are included in the terminal
*HQHULFHUURURU
Internal error of the probe
If the cable is tore off, insert it
again and screw it up
Pr1
Ensure that all the cables
are included in the terminal
Error of the room probe
If the cable is tore off, insert it
again and screw it up
Pr2
Ensure that all the cables
are included in the terminal
Error of the room probe
If the cable is tore off, insert it
again and screw it up
%ODVWLQJWLPHWRRORQJ
Check if the evaporator is
blocked with ice
Leave the door open for at
least 15 min to melt the ice
Check if the product is loaded
correctly and does not exceed
Lighten the load of trays
and grills
Check if the internal fan is
spinning
Contact the assistance
Ensure that the laboratory
temperature is not too high
and with high percentage of
humidity
Contact the assistance
Failed conservation of the food
at the end of the blasting cycle
Contact the assistance
PAP
Porta aperta
Porta aperta
Controllare che la porta sia
chiusa correttamente
SnP
Check the correct
insertion of the probe
Probe not inserted
Insert the probe more deeply or
continue time-based blast chilling
General product information:
FRGH%6)MN]LGHQWLÀFDWLRQRIVLQJOHSDUWLFXODUFRGHRIWKHIDPLO\%6)%ODVW&KLOOHU6KRFN)UHH]HU
"BSF" TYPE OF PRODUCT
possible options:
BSF = Blast Chiller - Shock Freezer
"j" grids or pans capacity of EUT
possible options:
03TS = capacity: 3 grids or pans
NDGGLWLRQDOFRQÀJXUDWLRQRI(87
possible options:
CY With unit - manual defrosting system