www.atestgaz.pl
Cable glands
• Cable diameter range
• Number of glands
5 – 10 mm
5
Cross-section of wires for clamping terminals
Cross-section of wires for the
valve connector
1 – 2.5 mm
2
1.5 – 4 mm
2
Enclosure material
ABS
Lifetime
10 years
Mandatory periodic inspection
Every year
Lifetime of consumables
Table 18: Technical specification
11
List of consumables
Consumables
Lifetime
No.
Manufacturer
Product code
Battery 12V 1.3 Ah
(EcoAlpa Control Unit)
1 year
-
-
-
Fuse 3.15 A
-
B2
-
Glass fuse 20 x 5 mm, T3,
15 A (slow)
Battery 12V 5 Ah (ZMZ) 1 year
-
-
-
Fuse 10 A
-
B1
-
Glass fuse 20 x 5 mm, T10
A (slow)
Table 19: List of consumables
12
Product marking
Product code
Device
PW-054-LED2-1212
EcoAlpa LED2 Control Unit with a battery backup power voltage
PW-054-LED2-230
EcoAlpa LED2 Control Unit without a battery backup power voltage
PW-054-P17-230
EcoAlpa P17 Control Unit without a battery backup power voltage,
suitable for collaboration with solenoid valves with the solenoid
voltage of 230 VAC
PW-054-P17-XEF1212
EcoAlpa P17 Control Unit without a battery backup power voltage,
suitable for collaboration with solenoid valves with the solenoid
voltage of 12 VDC
PW-054-P17-XEF1240
EcoAlpa P17 Control Unit with a battery backup power voltage, suitable
for collaboration with solenoid valves with the solenoid voltage of
12 VDC
Table 20: Product marking
13
Appendices
[1]
DEZG008-ENG – EU Declaration of Conformity – EcoAlpa
s. 28|28