www.atestgaz.pl
The foregoing tests can be carried out by a trained employee of the user. Any irregularities
revealed during tests and possible doubts with regard to technical condition of equipment
must be immediately reported to the system manufacturer. The EcoAlpa control unit
automatically reminds that the foregoing tests are required.
annual inspections shall be carried out by an authorized test company or a test team of the
manufacturer upon the need of inspection is claimed.
9.6.1
Replacement of consumables and fast wearing parts
Lifetime of consumables and fast wearing parts is listed in Table 18.
9.6.1.1 Replacement of battery in EcoAlpa Control Unit
To replace the EcoAlpa battery follow the procedure below:
disconnect the control unit from power voltage,
remove the lid,
undo bolts of the battery holder,
disconnect the battery,
replace the battery with a new one,
repeat the disassembling procedure in the reverse order.
9.6.1.2 Replacement of battery in ZMZ Module
To replace the ZMZ battery follow the procedure below:
disconnect from power voltage,
remove the module lid,
disconnect the battery,
replace the battery with a new one,
repeat the disassembling procedure in the reverse order.
9.6.2
Maintenance
The device does not require any specific maintenance except for cleaning the outer surface of the
enclosure. The enclosure should be cleaned by means of a soft cloth moistened with water and a bit of a
mild detergent.
9.7
Utilization
This symbol on a product or on its packaging indicates that the product
must not be disposed of with other household waste. Instead, it is the
user's responsibility to ensure disposal of waste equipment by handing it
over to a designated collection point for the recycling of waste electrical
and electronic equipment. The proper recycling of your waste equipment
at the time of disposal will help to conserve natural resources and ensure
that it is recycled in a manner that protects human health and the
environment. Information about relevant designated collection points can
be obtained from the Local Authority, waste disposal companies and in the
place of purchase. The equipment can also be returned to the
manufacturer.