44
© 2020 ATEÏS Europe B.V.
6.5.4.
To configure relay outputs
Relay outputs are activated by variables. Refer to
Advanced config > Variables
section to learn more
about variables.
Output is activated if assigned variable is set to 1.
Output is deactivated if assigned variable is set to 0.
Following variables can activate and deactivate relay outputs.
Variable description
Variable name
Global state
state
System state
systemstate
Events
events
Configuration OK
configuration
Security mode
security
Global evacuation state
evac
Normal level
normal
Night level
night
Attenuated level
attenuated
Loud level
loud
Line X busy (X = 1 to 6)
outXbusy
Line X music (X = 1 to 6)
outXmusic
Line X evacuation (X = 1 to 6)
outXevac
0dB output busy
out7busy
0dB output music
out7music
0dB output evacuation
out7evac
Audio input X state (X = 1 to 2)
inXstate
Audio input X routed (X = 1 to 2)
inXrouted
Call station X state (X = 1 to 2)
csXstate
Call station X routed (X = 1 to 2)
csXrouted
Front microphone state
micstate
Front microphone routed
microuted
User decoder X state
decXstate
User decoder X routed
decXrouted
Any message routed
msgrouted
Audio encoder X active (X = 1 to 2)
encXactive
Audio encoder X activity detected (X = 1 to 2)
encXaudioactivity
Audio decoder X active (X = 1 to 4)
decXactive
Audio decoder X stream time-out (X = 1 to 4)
decXtimeout
Call station X connection
csXconn
Remote input X value (X= 1 to 6)
reminX
Remote input X fault status (X = 1 to 6)
reminXstate
Voltage input X value (X = 1 + 6 to 2 + 6)
reminX
Front knob X fault status (X = 1 to 6)
potXstate
Relay output X value (X = 1 to 6)
remoutX
Firmware
firmware
Ethernet link
ethlink
Command interface connection
cmdconn