42
© 2020 ATEÏS Europe B.V.
6.5.2.
To configure front knobs
§
Click on
Front Knob 1
or
Front knob …
6.5.2.1.
Front knob defined as analog input
Parameter
Access
Description
Mode
Read / Write
Logical (ON / OFF) or Analog or Selector
Value for minimum
position
Read / Write
Minimum scaler value if knob is turned on minimum position
Value for maximum
position
Read / Write
Maximum scaler value if knob is turned on maximum position
Min
Read / Write
Click on Calibrate after turning knob on minimum position
Max
Read / Write
Click on Calibrate after turning knob on maximum position
§
Click on Apply changes to save modifications.
§
Click on Back to list to jump to
Basic config > Logic I/O page.
6.5.2.2.
Front knob defined as selector input