© 2020 ATEÏS Europe B.V.
Parameter
Access
Description
Mode
Read / Write
Logical (ON / OFF) or Analog or Selector
Number of positions
Read / Write
Number of positions defined for the selector
Position X
Read / Write
Click on Calibrate after turning knob on corresponding position
§
Click on Apply changes to save modifications.
§
Click on Back to list to jump to
Basic config > Logic I/O page.
6.5.3.
To configure voltage inputs
§
Click on
Voltage Input 1
or
Voltage Input 2.
Repeat Period
is displayed only if
Repeat Activated Event
option is selected.
Parameter
Access
Description
Mode
Read / Write
Logical (ON / OFF)
Normally Closed
Read / Write
Normally open (default) = Active if contact closed – Normally closed
= Active if contact open
Monitored
Read / Write
4 states: No connection, Open, Closed, Short-circuit – Fault report
if no connection or short-circuit
Fault when not active
Read / Write
Voltage input used as fault report for third party equipment (power
supply, amplifier…)
Repeat Activated
Event
Read / Write
Event is repeated periodically as long as voltage input is active
(incrementation, decrementation…)
Repeat Period
Read / Write
Repetition period, in case Repeat Activated Event option is selected
Confirmation delay
Read / Write
Pulse duration to avoid false input activation
§
Click on Apply changes to save modifications.
§
Click on Back to list to jump to
Basic config > Logic I/O page.