Dialing Mode
This option sets the dialing mode for the
tie line.
●
Touch-Tone
●
Rotary (default)
Dial Tone
This option determines whether the dial tone
originates from the remote or local end of the tie line, or
both (you receive a second dial tone).
●
Remote (default)
●
Local
Answer Supervision Time
This option sets a time limit
in milliseconds (ms) for the remote station to signal the
calling station.
●
20 to 4800 ms (increments of 20 ms)
●
300 ms (default)
Tie Line Disconnect Time
This option sets a time limit
for the release of the E or M lead.
●
140 to 2400 ms (increments of 10 ms)
●
300 ms (default)
Your choice of signaling format (signaling mode and type)
depends on the particular application. Using Table 1-4
“Tie Line Preferred Signaling Formats,” you can
determine tie line compatibility between the MERLIN II
System and other systems.
Theory of Operation 1-49