TABLE 3-5 Display Console Administration (continued)
Procedure: Slide T/P switch to P, press Conference button
F e a t u r e
twice, then follow steps for feature
Night Service,
Enhanceed
(continued)
To set times for
7
Night Service to
go on and off
automatically
(continued)
To record
current day for
Night Service
with Time Set
Press [More], [Night], [More], [DayofWk] .
with
Time Set
To suspend
Night Service
To get a
printout of
8
9
10
1
2
3
4
5
1
2
3
4
5
1
2
3
Dial number of day of week:
0 = Sunday
4 = Thursday
1 = Monday
5 = Friday
2 = Tuesday
6 = Saturday
3 = Wednesday
Dial “off” time using 24-hour format (0000 through 2359).
Press
[Enter]
and Repeat steps 2 through 9 for each day of
week. (Don ‘t set on or off time if Night Service should stay on for
entire 24 hours.)
Press Conference to return to the administration menu.
.
Use Backspace or Drop to remove the current entry.
Dial number of current day of week:
0
= Sunday
4 = Thursday
1 = Monday
5 = Friday
2 = Tuesday
6 = Saturday
3 = Wednesday
Press
[Enter]
.
Press Conference to return to the administration menu.
Press
[More], [Night], [More], [DayofWk]
.
Use Backspace or Drop to remove the current entry.
Dial 9.
Press
[Enter]
.
Press Conference to return to the administration menu.
Press
[More], [More], [Print], [More], [More], [More]
.
Enhanced Night
Service
Information
Press
[NiteSrv]
to begin printing.
Press Conference to return to the administration menu.
3-88 Optional Features
Summary of Contents for administration and
Page 40: ...FIGURE 1 9 System architecture Theory of Operation 1 37 ...
Page 175: ...Top cover Front cover FIGURE 2 27 Control unit covers Testing the System 2 107 ...
Page 211: ...FIGURE 3 I A MERLIN II System Display Console The Administrator Attendant Console 3 3 ...
Page 213: ... FIGURE 3 2 A BIS 34D Console The Administrator Attendant Console 3 5 ...
Page 331: ...General Tests 4 55 Reaming the Control Unit 4 55 Testing Outside Lines 4 56 ...