Examples of the results display are shown below: (Figures 34 & 35)
To determine the condition of the tested Deep Cycle Batteries, refer the
Volts
reading – State of Charge (
should not fall below 12.60V when fully
charged for Lead Acid Batteries, 12.85V for Gel Batteries and 12.80V for
AGM Batteries
) and the Internal Resistance [
Int. R
] of the tested battery
should
not be more 25 mOhm
readings.
Batteries that had been left idle for long periods can still be tested with this
analyser. To perform the test, just clamp the analyser clips onto the battery
terminals and it will display the screen (Fig.36) as shown if its voltage falls
below the normal 12.0 volts.
18. Press
key to continue and the display will show: (Fig.37)
Fig.34
Fig.36
Battery: Good
Measured: 404 CCA
Volts: 12.26 V
Int. R: 6.68 mOhm
Exit to Menu
Battery voltage is
below 12.00 Volts!
[Enter] to proceed
Battery: Replace
Measured: 86 CCA
Volts: 12.26 V
Int. R: 31.52 mOhm
Exit to Menu