___________________________________________________________________________________
‐
23
‐
12‐1015 rev‐B
User’s Manual Version 14.12
16. Here it let you to select the surrounding temperature that you are working
with the battery. If the surrounding temperature is for example 15°C, then
select [Above (32
°
F/0
°
C)] by pressing key and then press key.
Then the results will show on the LCD display.
17. To print out the results, just press
key on the Analyser, the printer will
start printing.
Interpretations of the above (Fig.33) results:
1.
Battery:
Good
A very straight forward display of the final results basing on the evaluation of
the tested condition. ‘
Good
’ indicates the battery in good condition.
‘
OK-Recharge
’ means that the battery is OK but needs to recharge as its
state of charge is low. ‘
Replace
’ indicates that the battery needs to be
replaced. If not, the battery will fail anytime without any warning.
2.
Rating:
630 CCA
The battery capacity rated output is normally stated on the label for car
batteries. For other batteries, please refer the chart provided or check on
information provided on the label.
3.
Measured:
565 CCA
It means that the battery tested has a capacity of 565 CCA power available.
CCA ratings has been used here, therefore the tested result is in CCA and if
other rating (DIN, SAE, JIS, IEC, CA, or EN) were selected, it will base on
the respective rating to calculate and show the results in that selected
rating.
4.
Volts :
12.50V
The volts here indicated the State of Charge (SOC) of the tested battery
which is 12.50V during open circuit condition. [Above 80% SOC for WET
batteries by referring to the table below.]
Battery: Good
Rating: 630 CCA
Measured: 565 CCA
Volts: 12.50 V
Int. R: 4.78 mOhm
Life: 91 %
[Exit] to Menu
Fig.33
1
2
4
3
5
6