OPERATION
22
OPERATION INSTRUCTIONS FOR HYAMP jr.
Model 3030D
A. POWER UP:
Check to be sure that the correct input line voltage has been selected on the rear panel,
either 115 volts AC or 230 volts AC. Connect the power-input plug into its socket on the
rear panel of the instrument. Connect the male end of the plug to the outlet receptacle.
Please be sure that the safety ground on the power line cord is not
defeated and that you are connecting to a grounded power source. Also
connect the rear panel chassis ground for additional safety.
Turn on the POWER switch located on the lower left-hand side of the front panel. Upon
powering the instrument up a POWER ON SELF-TEST (POST) will be automatically
performed. This test will check for the condition of the ram chips, led indicators, PCBs
and other critical components. In addition the display will show the following message.
ARI HYAMP JR.
3030D VER : X.X
The instrument will recall the last memory program that was active and the display will
show the parameters that were programmed into that memory. The instrument is now
ready for operation.
B. SETUP PROCEDURE:
1. Output Current Setting
Please press the SET key, the display will show:
CURRENT = XX.XA
Please use the Up (
∧
) or Down (
∨
) arrow keys to adjust the Current setting, then press the
EXIT key to store the current setting and return to the Run mode, or press the SET key to
advance to the next parameter. The maximum current which may be entered is 30.0
Amps. Any value above this will produce an ERROR message.
2. High Limit Setting
Please press the SET key until arriving at the HI-LMT setting. The display will show:
HI-LMT = XXX m
Ω
Please use the Up (
∧
) or Down (
∨
) arrow keys to adjust the value of the High Limit
resistance trip point then press the EXIT key to store the setting and return to the Run
mode, or press the SET key to advance to the next parameter. The unit of measure is in
CAUTION
Summary of Contents for 3030D
Page 4: ......
Page 5: ...SECTION 1 OPERATORS MANUAL ...
Page 38: ...OPTIONS 34 This page left intentionally blank ...
Page 39: ...SECTION 2 SERVICE MANUAL ...