90
“MEDICAL” ALARM 4+2 CODE
“MEDICAL” ALARM 4+2 CODE
- P195E 21E (Value 00-FF)
“MEDICAL” ALARM RESTORE 4+2 CODE
“MEDICAL” ALARM RESTORE 4+2 CODE
- P195E 22E (Value 00-FF)
SIA ALARM REPORT CODES
The programmable SIA alarms events below are changed by programming a value from 1-14 (see chart below). For
example, to send the SIA “Emergency Alarm” code when a keypad panic is generated you must program a value of “7” at
location P197E1E.
From the chart below you can select one of 14 options that should cover most of the custom requirements. As an
example, if you required zone 10 to send a fire alarm you would program a value of 4 at address P196E10E. When you
program a particular alarm type at any of the locations below, the panel will automatically send all of the other
associated reports (if applicable) from the chart. Using the same example, if zone 10 was bypassed and the SIA report
code was set to type 4, the panel will send an “FB” event code to indicate that it is a fire zone bypass instead of the default
burglar alarm bypass (BB).
ZONE ALARM SIA REPORTING CODES
ZONE ALARM SIA REPORTING CODE -
P196E 1-16E (Value from 1-14 taken from the chart below)
“PANIC” ALARM SIA REPORTING CODES
“PANIC” ALARM SIA REPORTING CODE
-
P197E 1E (Value from 1-14 taken from the chart below)
“FIRE” ALARM SIA REPORTING CODES
“FIRE” ALARM SIA REPORTING CODE
-
P197E 2E (Value from 1-14 taken from the chart below)
“MEDICAL” ALARM SIA REPORTING CODES
“MEDICAL” ALARM SIA REPORTING CODE
-
P197E 3E (Value from 1-14 taken from the chart below)
PANEL DIAGNOSTIC & DEFAULTS OPTIONS
PANEL SOFTWARE VERSION NUMBER
PANEL SOFTWARE VERSION NUMBER
- P200E 1E
This location will display the software version of the panel.
KEYPAD ADDRESS NUMBER
KEYPAD ADDRESS NUMBER
- P200E 2E
This location will display the keypad number of the keypad currently in program mode.
AREAS ASSIGNED to the KEYPAD
AREAS ASSIGNED to the KEYPAD
- P200E 3E
This location will display the Areas assigned to the keypad currently in program mode.
DISPLAY TIME-ZONES CURRENTLY ACTIVE
DISPLAY TIME-ZONES CURRENTLY ACTIVE
- P200E 4E
This location will display which of the 8 Time-zones are currently on.
DISPLAY BATTERY VOLTAGE
DISPLAY BATTERY VOLTAGE
- P200E 5E
This location will display the system battery voltage measured by the panel.