64
Option 3 - Output 3
Option 7 - Output 7
Option 4 - Output 4
Option 8 - Output 8
The <CONTROL> button at a Keypad can be assigned to an Output or multiple Outputs. If the <CONTROL> button is not
assigned to an Output a User cannot access Local Control Mode (by pressing the <CONTROL> button) and turn that
Output On or Off from the Keypad. This feature is useful if Outputs are being used to control devices such as lights, etc
and you wish to be able to turn them On or Off from a keypad. By limiting the access to Outputs via the <CONTROL>
button you can avoid conflict with alarm outputs (eg the User can be denied access to outputs that are being used for
alarm functions).
KEYPAD PANIC ALARM to OUTPUT
KEYPAD PANIC ALARM to OUTPUT -
P84E 1-8E (includes <PANIC>, <1> & <3> or <CONTROL> & <CHIME>)
Option 1 - Output 1
Option 5 - Output 5
Option 2 - Output 2
Option 6 - Output 6
Option 3 - Output 3
Option 7 - Output 7
Option 4 - Output 4
Option 8 - Output 8
A Keypad generated Panic Alarm (either pressing the <PANIC> button, <1> & <3> or <CONTROL> & <CHIME>
together) can be assigned to an Output or multiple Outputs. This can be used to operate an audible or visual alarm
connected to the Output.
KEYPAD FIRE ALARM to OUTPUT
KEYPAD FIRE ALARM to OUTPUT -
P85E 1-8E (includes <A> & <B> or <4> & <6>)
Option 1 - Output 1
Option 5 - Output 5
Option 2 - Output 2
Option 6 - Output 6
Option 3 - Output 3
Option 7 - Output 7
Option 4 - Output 4
Option 8 - Output 8
A Keypad generated Fire Alarm (either pressing the <A> & <B> or <4> & <6> together) can be assigned to an Output or
multiple Outputs. This can be used to operate an audible or visual alarm connected to the Output.
KEYPAD MEDICAL ALARM to OUTPUT
KEYPAD MEDICAL ALARM to OUTPUT -
P86E 1-8E (includes <B> & <CHIME> or <7> & <9>)
Option 1 - Output 1
Option 5 - Output 5
Option 2 - Output 2
Option 6 - Output 6
Option 3 - Output 3
Option 7 - Output 7
Option 4 - Output 4
Option 8 - Output 8
A Keypad generated Medical Alarm (either pressing the <B> & <CHIME> or <7> & <9> together) can be assigned to an
Output or multiple Outputs. This can be used to operate an audible or visual alarm connected to the Output.
KEYPAD DURESS ALARM to OUTPUT
KEYPAD DURESS ALARM to OUTPUT -
P87E 1-8E
Option 1 - Output 1
Option 5 - Output 5
Option 2 - Output 2
Option 6 - Output 6
Option 3 - Output 3
Option 7 - Output 7
Option 4 - Output 4
Option 8 - Output 8
A Keypad generated Duress Alarm (see P25E2E) can be assigned to an Output or multiple Outputs. This can be used to
operate an audible or visual alarm connected to the Output. A Duress alarm is created when the alarm is Disarmed with
the Duress digit preceding a valid User Code.
KEYPAD TAMPER SWITCH ALARM to OUTPUT
KEYPAD TAMPER SWITCH ALARM to OUTPUT -
P88E 1-8E
Option 1 - Output 1
Option 5 - Output 5
Option 2 - Output 2
Option 6 - Output 6
Option 3 - Output 3
Option 7 - Output 7
Option 4 - Output 4
Option 8 - Output 8
Summary of Contents for Avolution S series