93
‘
S series
’
PROGRAM
SUMMARY GUIDE
The following program summary is an abbreviated version of all the panel program addresses. This is intended as a quick
guide to finding a program address. In many address locations, there is a main address (e.g. “
P1E
”), then a sub address
(e.g. P1E “
1E
”). You must enter in the main address number, followed by the sub address, then you can enter the actual
data. The program addresses are in numerical order with page references beside them so you can get more detailed
information if required.
This Summary is split into 11 headings. These are;
1) Users Programming
Page 38
8) Time Zones
Page 77
2) Miscellaneous Panel & Clock Settings
Page 44
9) Dialler
Page 78
3) Outputs
Page 49
10) Telephone Numbers
Page 82
4) Areas
Page 52
11) Miscellaneous 4+2 Program Options
Page 88
5) Keypads
Page 58
12) SIA Report Codes -
Page 90
6) Key-Switches
Page 66
13) Panel Diagnostic & Default Options
Page 90
7) Zones
Page 67
USERS
Programming User Codes
P1E
1-100E
User Code 1-100 -
Default for User Code # 1 (P1E1E) = 1234 Codes can be 1-6 or 4-6 digits
.
Page 38
(where 1E = User Code #1 to 100E = User Code #100)
NOTE:
The 100 Users can be keypad Code, Radio or Access key Users. They can be mixed but the Maximum is 100 Users.
The User type MUST be set to “0” (P2E User# E) for a code to be entered at the above address
.
User Type (Code/Radio/Access Tag-Card)
P2E
1-100E
User # 1-100 Type -
0 = Keypad Code User {PIN}
Page 38
(Default = 0)
1 = Radio User (Users 21-100 only)
2 = Access Tag/Card User
3 = Both Code and Access Tag/Card User {Tag + PIN)
4 = Either Code or Access Tag/Card User {Tag or PIN}
User Area Assignment
P3E
1-100E
User # 1-100 Area -
1 = Assigned to Area “A”
Page 39
(Default = 1)
2 = Assigned to Area “B”
User Code Access Options
P4E
1-100E
Users 1-100 Access Options
(Default 1-4
)
1 = Code can Arm Area
Page 39
(Default = 1,3,4)
2 = Code can arm Stay Mode
3 = Code can Disarm Area
4 = Code can disarm Stay Mode
5 = Code is a Security Guard Code
6 = Code will Arm Latchkey Mode
7 = Call Divert Code
8 = Can View Event Memory
User Code Privileges
P5E
1-100E
Users 1-100 Privileges
1 = User can Change their Code
Page 40
(Default User 1 = 2,3,4,5,6,7,8)
2 = User can Change All Codes
(Default User 2-100 = All Off)
3 = User can Allow Access to Installer Mode/Edit all Codes
4 = User can Change Telephone Numbers
5 = User can Change the Clock
6 = User can Change DTMF Command Codes
7 = User can Learn New Radio Devices
8 = User can Force a Download to Callback Number
Radio User Type
P7E
21-100E Radio User 21-100 Type
0 = General Pendant Type
Page 40
(Default = 0)
1 = Crow Freelink Pendant
21 = Ness Pendant
Radio User Privileges
P8E
21-100E Radio Users 21-100 Privileges
1 = Pendant Can Disarm at All Times
Page 41
(Default = 1)
2 = Pendant Causes Immediate Panic
3 = Pendant Causes Delayed Panic ( 1.5 Sec)
4 = Pendant only works during Entry Delay
5 = This User is a Duress Code (Users 21-100)
6 = Spare
7 = Spare
8 = Spare
Summary of Contents for Avolution S series