SIMPLE TO USE

The easy-to-understand icons, combined with a three-character display, 
provides visual feedback enabling simple arming, disarming, and a 
variety of other functions.   

PLEASE TAKE A MOMENT

To learn the range of features of your system, please read through this 
user’s guide thoroughly.  All icons and keypad operation are completely 
described.

Thinline™ Series Icon Keypads

System Functions 

Resetting Sensors 

Use this function to reset the smoke detectors after an alarm has 
occurred.  Press and hold the RESET (2) key for two seconds.   The Flame 
icon will clear from the display when the Sensor Reset operation is 
complete and the smoke detectors are reset.

User Codes

+[your code]+[user [user code]+[level]

This function allows you to Add or Delete user codes.  Each user is 
assigned 3 settings:
The 

User Number

 is how the system identifes a user.

The

 User Code

 is the four digit number a user enters into the keypad to 

arm, disarm or to perform other system operations.
The 

User Level

 - the user is also assigned a level of authority (Master, 

Standard, Limited, or Scheduled) to determine the functions the user 
can access.  See below for User Code authority levels.

•  Press and hold the CODE key (4) until the keypad beeps once and 
enter your user code.

•  Enter the four-digit user code to assign to the user number or 0000 to  
  delete an existing user.
•  Enter the authority level (1-4)

Level 3 = Standard User 
The Standard authority level can perform all system functions 
except adding or deleting user codes.
Level 4 = Master User in 
The Master authority level can perform all system functions.

Zone Status 

Use this function to display burglary protection zones that are faulted 
while the system is disarmed.  Any faulted burglary zones are shown in the 
3-character display allowing you to correct the problem before arming.

Door Chime 

You can enable monitor for all Perimeter zones in the system to sound a 
doorbell chime at the keypad anytime a zone is opened.  Press and hold 
the CHIME (5) key for two seconds.  The Door icon will display and the 
doorbell chime sounds.  Pressing the CHIME key again for two seconds 
turns off this function.

Easy Exit 

This function allows you to exit your home while the system is armed.  
Press and hold the EXIT (8) key until the exit countdown begins to 
display and then exit.  The system automatically arms again after the 
countdown completes.

Arming the System

Arming with a Code or Proximity Credential

While the Thumbs Up icon is displaying, enter your user code or 
present a proximity credential to begin the exit countdown.  Arming is 
delayed until the end of the countdown.  Pressing the INST key during 
the exit countdown immediately arms the system and removes all 
entry/exit delays.  An alarm would immediately occur should an exit 
door be opened.

Arming with Shortcut Keys 

While the Thumbs Up icon is displaying, press and hold the ALL, HOME, 
PERIM or SLEEP key for two seconds to arm your system.

 

ALL arms the entire system.

 

HOME or PERIM arms the Perimeter zones leaving the 

 

Interior disarmed.

 

SLEEP arms the Perimeter and Interior zones leaving the  

 

sleeping area disarmed. (optional)

 Arming with faulted Zones (Thumbs Down)

Thumbs down displays and the keypad sounds four short 
beeps when a burglary zone is faulted while arming the 
system. The zone number is shown in the 3-character 
display.  If the problem is simply an open door or window, 
press the Back Arrow key, correct the problem, and 
try arming again. If the problem cannot be corrected, 
press the Select Key under BYPASS to go ahead and arm 
the system.  A zone remains bypassed until the system 
is disarmed.  If no selection is made, the system will 
automatically force arm any faulted burglary zones without 
bypassing.

Disarming the System

Disarming with a Code or Proximity Credential

When the Armed (Lock) icon is displaying, enter your user code or 
present a proximity credential to disarm the entire system.

Disarming During an Alarm

Enter your user code or present a proximity credential to silence the 
siren leaving the system armed.     

After a user code is entered to silence the siren, CANCEL/VERIFY 
displays allowing you time to investigate a burglary alarm prior to 
disarming the system. 

  If a valid alarm has 

not

 

occurred, choosing CANCEL  

 

 

disarms the system and sends a Cancel or Abort message  

 

to the Central Station. 

 

If the alarm is valid, choosing VERIFY sends a Verify  

 

 

message to the Central Station.  The system remains    

 

armed to provide continued intrusion detection.

ZONES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

ProTELEC Alarms User Guide