79
Option 1
Step to next Number
- If more than one telephone number is programmed, this option will force the dialler
to step through each number after a call. If this option is off the dialler will make all calls to the first number
before moving on to the next number.
Option 2
Upload/download uses Call-back Number -
A Telephone number can be programmed as a Call-back
number. If this option is turned on, and a PC contacts the panel a direct connection cannot be made with
the PC. The panel will hang-up the call and dial the PC back on the Call-back number. The PC user can only
select the “Call-back” option to make a connection with the panel if this option is turned on. For some
modems you might have to program the reporting format for the call-back number to be type “0” otherwise
the panel may not connect with the modem during a call-back request.
Option 3
Upload/download only if Disarmed -
If this option is turned on, and a PC attempts to contact the panel
while the alarm is Armed a direct connection cannot be made as the panel will not answer the call. If the
panel is Disarmed a connection can be established.
Option 4
Send Test Calls Only if Armed -
If this option is On the panel will only send a daily test call if it is Armed. This
option assumes that the normal arm/disarm signals sent on a daily basis can serve as a test and that the
connection only needs to be verified daily if the panel is left in the armed state for periods longer than 24
hours.
Option 5
Test Time Period is in days
- If this option is turned off the test time period (P175E5E) will be set in hours. If
this option is turned on the test time period will be in days.
Option 6
Hold line open following Domestic/Voice report for DTMF control -
If this option is On the dialler will
keep the telephone line open after being kissed-off following a Domestic or Voice alarm call so that the
person at the phone can then use their DTMF codes to arm/disarm the system or turn on the optional
microphone if required.
Option 7
First to Open Last to Close Reporting
- If this option is on and the alarm is split into two Areas, then the
“Arm” report to the monitoring station will only be sent when both areas are armed and it will be a single
report on Area A account code (last to close). On Disarming of the alarm the disarm report will be sent
when either Area is disarmed (first to open). Only one disarm report will be sent using the Area A account
code. If zones in both areas are bypassed, the bypass report for all zones will only be sent when both areas
are armed (last to close) but the Bypass restore reports will be sent only when the Area associated with the
zone is disarmed. In this way if an area remains armed and it’s associated bypassed zone/s are still bypassed
the monitoring station knows that the bypasses have not been removed yet.
Option 8
Answer After 1 ring for Two Way Voice Call-back Mode -
If this option is turned ON and a full duplex voice
board is fitted, the panel will answer an in-coming call after 1 ring and automatically enter full duplex two
way voice mode. For full duplex voice mode to be active for call-back, option 5 at P183E must be turned OFF.
See also the instructions on Page 118
AUTO-ANSWER RING COUNT
AUTO-ANSWER RING COUNT -
P175E 3E (Value 0-99)
If the dialler is set to answer an in-coming call for remote control or upload/download the number of rings before
answering the call can be set at this location. There is also a manual answer function described on page 36.
TEST CALL START TIME
TEST CALL START TIME -
P175E 4E (Value 0000-2359)
If the dialler is set to send Automatic Test Calls, the start time for the first call is set at this location. This allows the test call
to be linked to a quiet period where the line would not normally be used (eg 2300)
TEST CALL TIME PERIOD
TEST CALL TIME PERIOD -
P175E 5E (Value 0-255 Hours)
When reporting in Contact ID format the panel can send regular test calls to the monitoring company to check the
integrity of the panel and the line. The regularity of the test calls is set at this location. It would normally be set to a value
of 24 so that a test call is sent one a day. The start time for the first test should also be set at location P175E5E.