ARMED ZONE ENTRY DELAY TIME
ARMED ZONE ENTRY DELAY TIME -
P144E 1-16E (Value 0-9999 Seconds)
Each Zone has it’s own Entry Delay time when in the Full Armed State. The delay can be programmed from 0-9999
seconds in one second increments. If the entry delay is set to “0” the zone will be an instant zone.
STAY MODE ZONE ENTRY DELAY TIME
STAY MODE ZONE ENTRY DELAY TIME -
P145E 1-16E (Value 0-9999 Seconds)
Each Zone has it’s own Entry Delay time when in Stay Mode. The delay can be programmed from 0-9999 seconds in one
second increments. If the entry delay is set to “0” the zone will be an instant zone.
ZONE RE-TRIGGER COUNT
ZONE RE-TRIGGER COUNT -
P146E 1-15E (Value 0-15 Triggers)
Each Zone has it’s own alarm Re-trigger Count. A value of 0 programmed at this location results in unlimited alarms for
that zone during an armed period but a count of 1-15 will shut down the zone once the programmed count has been
reached. Disarming the alarm will reset this count.
ZONE ALARM CONTACT ID REPORT CODE
ZONE ALARM CONTACT ID REPORT CODE -
P157E 1-16E (3 digit event code)
Normally a zone alarm would default to reporting a standard “Burglar Alarm” code of “130” when the zone activates. If
the zone is not being used as a burglar alarm and you need to identify the correct type of alarm event you can change
the event code at this location (eg if zone 5 was a fire sensor you could program a value of “110” at P157E5E).
ZONE NEAR ALARM CONTACT ID REPORT CODE
ZONE NEAR ALARM CONTACT ID REPORT CODE -
P158E 1-16E (3 digit event code)
If the Near & Confirmed zone alarm reporting option was active the default report code for a “Near Alarm” is “138”
when the zone activates for the first time. There should be no reason to change this code but if some special application
was to be used it can be changed at this location.
ZONE CONFIRMED ALARM CONTACT ID REPORT
CODE
ZONE CONFIRMED ALARM CONTACT ID REPORT CODE -
P159E 1-16E (3 digit event code)
If the Near & Confirmed zone alarm reporting option was active the default report code for a “Confirmed Alarm” is
“139” when a second zone activates within 45 minutes of the near alarm. There should be no reason to change this
code but if some special application was to be used it can be changed at this location.
ZONE ALARM VOICE MESSAGE NUMBER
ZONE ALARM VOICE MESSAGE NUMBER -
P160E 1-16E (Value 0-99)
If the Optional Voice Board is fitted and the alarms are to be reported in Voice Format, each zone can be assigned a
voice message to report the alarm type. If this location is set to “0” the zone will not report via the dialler. If Option 1 at
P46E is turned on (use near and confirmed alarm reporting) the panel will not send an alarm in this format.
ARMED ENTRY DELAY to OUTPUT
ARMED ENTRY DELAY to OUTPUT -
P161E 1-16E
Option 1 - Output 1
Option 5 - Output 5
Option 2 - Output 2
Option 6 - Output 6
Option 3 - Output 3
Option 7 - Output 7
Option 4 - Output 4
Option 8 - Output 8
If the alarm is Armed and a delay zone triggers the entry delay it can also beep an Output to warn that the entry delay is
counting down and the alarm should be turned off.