29
After the system configuration has been reset back to defaults, all values, options & Codes will be set to the values shown
in the Program Summary as defaults. These values have been chosen as the most common set-up for the majority of
systems.
To reset partial defaults:
Press <
PROGRAM
> - <
P200E9E
> - <
ENTER
>
3 short beeps if OK - 1 long beep if error
The partial reset to defaults will return all User Codes, the Installer Code and Telephone Numbers back to the values
shown in the Program Summary as defaults. These values have been chosen as the most common set-up for the majority
of systems.
TO EXIT PROGRAM MODES USING LED KEYPAD
To exit either program mode when you have finished programming:
Press <
PROGRAM
> - <
ENTER
>
Program light goes out
If no buttons are pressed for 4.5 minutes the panel will automatically exit program mode
The panel is now back in Run Mode, any program changes you have made will have replaced previous values and be in
effect.
Note:
During programming Tampers and 24 hour alarms are disabled which allows quiet access to the panel, detectors
and external siren units, etc. On exiting program mode, all inputs are scanned and if any tampers or 24Hr alarms are
present an activation will occur.
TO EXIT PROGRAM MODES USING LCD KEYPAD
There are two ways to exit Program Mode with an LCD keypad. To exit either program mode when you have finished
programming:
Repeatedly press the <
PROGRAM
> button until the display shows
“<ENTER> TO EXIT”
Now press <ENTER> to exit Program Mode.,
OR
Press and hold the <PROGRAM> button for 2 seconds to exit program mode
If no buttons are pressed for 4.5 minutes the panel will automatically exit program mode
The panel is now back in Run Mode, any program changes you have made will have replaced previous values and be in
effect.
Note:
During programming Tampers and 24 hour alarms are disabled which allows quiet access to the panel, detectors
and external siren units, etc. On exiting program mode, all inputs are scanned and if any tampers or 24Hr alarms are
present an activation will occur.
HOW TO PROGRAM USING LCD KEYPADS
Access to Program Mode when using an LCD Keypad is exactly the same as when using an LED Keypad (see previous page
for access to program mode from power-up and normal run mode).
Once in Program Mode (either Client Mode or Installer Mode), the User can still enter program addresses directly at the
keypad to go straight to a particular address, as with the LED Keypad.
But the LCD Keypad also incorporates built-in menus that allow the Programmer to move through the Main-Menus using
the Up/Down Arrow keys. Also when at a data entry location, the Left/Right Arrows can be used. These special Function
Arrow keys are clearly marked on the keypad buttons (the position of the buttons can vary depending on the type of LCD
Keypad installed).
When navigating the Menus using the Arrow keys, each button has a special function depending on where you are within
the menus.
When you enter program mode the LCD Keypad display automatically defaults to “CLIENT:USER” (if in Client mode) or
“INSTALLER:USER” (if in Installer mode). By using the UP or DOWN Arrows, the user can cycle through all of the available
menus. The menus are accessed in a particular order based on the most frequently used program locations. All of the
Main and the Sub-Menus are shown on the following pages.