63
KEYPAD <B> BUTTON AREA OPTIONS
KEYPAD <B> BUTTON AREA OPTIONS
- P81E 1-8E (APPLIES TO PORTRAIT LCD KEYPAD ONLY)
Option 1 - <B> button can Arm
Option 2 - <B> button can Arm A Mode
Option 3 - <B> button can Disarm at All Times
Option 4 - <B> button can Disarm Stay Mode at All Times
Option 5 - <B> button can Reset Alarms
Option 6 - <B> button can Arm Latchkey Mode
Option 7 - <B> button can Disarm During Exit Delay
Option 8 - <B> button can Disarm Stay Mode During Exit Delay
Option 1
<B> button can Arm
- This option enables single button Arming using the <B> button. For single button
operation to work options 2 & 3 must be off at location P46E.
Option 2
<B> button can Arm Stay Mode
- This option enables single button Arming of Stay Mode using the <B>
button. For single button operation to work options 2 & 3 must be off at location P46E.
(NOTE: Following arming of Stay Mode, if the <ENTER> button is pressed, all entry & exit delays will be
reset to zero for that armed period).
Option 3
<B> button can Disarm at All Times
- This option enables single button Disarming using the <B> button.
For single button disarm operation to work options 2 & 3 must be off at location P46E
Option 4
<B> button can Disarm Stay Mode at All Times
- This option enables single button Disarming of Stay Mode
using the <B> button. For single button disarm operation to work options 2 & 3 must be off at location
P46E
Option 5
<B> button can Reset Alarms
- If this option is On, Pressing the <B> button (provided Option 3 is also On)
will reset an alarm condition without having to enter a user code.
Option 6
<B> button can Arm Latchkey Mode
- This option enables single button Arming of the alarm in Latchkey
report mode using the <B> button. For single button Arm operation to work options 2 & 3 must be off at
location P45E. When Latchkey Mode is set on Arming, any code without the Latchkey option (P4E Option 6)
used to Disarm the Alarm will cause a Disarm report to be sent via the dialler.
Option 7
<B> button can Disarm During Exit Delay
- This option allows single button Disarming using the <B>
button provided the Armed Mode exit delay is active. If the exit delay has expired the <B> button cannot be
used to disarm the alarm. For single button disarm operation to work options 2 & 3 must be off at location
P46E
Option 8
<B> button can Disarm Stay Mode During Exit Delay
- This option allows single button Disarming of Stay
Mode using the <B> button provided the Stay Mode exit delay is active. If the Stay Mode exit delay has
expired the <B> button cannot be used to disarm Stay Mode. For single button disarm operation to work
options 2 & 3 must be off at location P46E
KEYPAD to OUTPUT MASK
KEYPAD to OUTPUT MASK -
P82E 1-8E
Option 1 - Output 1
Option 5 - Output 5
Option 2 - Output 2
Option 6 - Output 6
Option 3 - Output 3
Option 7 - Output 7
Option 4 - Output 4
Option 8 - Output 8
A Keypad can be assigned to an Output or multiple Outputs. If a Keypad is not assigned to an Output a User cannot turn
that Output On or Off from the Keypad. This feature is useful when using the access control features of the panel, eg a
User may be allowed to operate more than one Output with their code but they will be limited to just the Output
assigned to the Keypad they are using.
<CONTROL> BUTTON to OUTPUT MASK
<CONTROL> BUTTON to OUTPUT MASK -
P83E 1-8E
Option 1 - Output 1
Option 5 - Output 5
Option 2 - Output 2
Option 6 - Output 6
Summary of Contents for Avolution S series
Page 119: ...119...