TSN
21286
-1 Rev.1 - Page 1
13
th October, 20
21
NEPTUNE KEYPAD TOUCH EM/HID
/MF
S/ALONE or WIEGAND IP65 (2x6)
MODELS
NEKPWST2S
PROGRAMMING
ENTER PROGRAMMING MODE
*
<MASTER CODE> #
(
default 888888
)
CHANGE MASTER CODE
0
<NEW MASTER CODE> # <REPEAT> #
ADD PIN USERS
1
<USER NUMBER (1-2000)> #
<PIN NUMBER> #
1
2
3
1
2
MASTER CODE MUST BE BETWEEN 6-8 DIGITS.
PRESS * TO EXIT PROGRAMMING
ADDITIONAL USERS CAN BE ADDED BY REPEATING STEPS 2 & 3
EXAMPLE
1 1 # 9384 # 2 # 2958 # 3 # 9876 # *
The programming above added 3 users with unique pin numbers
PIN NUMBERS MUST BE BETWEEN 4-6 DIGITS
PRESS * TO EXIT PROGRAMMING
ADD CARD USERS
1
<USER NUMBER (1-2000)> #
<BADGE CARD>
1
2
3
ADDITIONAL USERS CAN BE ADDED BY REPEATING STEPS 2 & 3
EXAMPLE
1 1 # <BADGE CARD> 2 # <BADGE CARD> *
The programming above added 2 users with cards
THE ABOVE METHOD IS PREFERRED FOR CARD PROGRAMMING
SO INSTALLERS CAN NOTE WHICH USER NUMBER EACH CARD
IS ASSIGNED TO.
PRESS * TO EXIT PROGRAMMING
DELETE USERS BY USER NUMBER
2
<USER NUMBER (1-2000)> #
1
2
ALL USERS CAN BE DELETED USING THE FOLLOWING STEPS
PIN NUMBERS MUST BE BETWEEN 4-6 DIGITS
PRESS * TO EXIT PROGRAMMING
2
0000 #
1
2
SET DOOR RELAY TIME
4
0 # (50ms / 5 seconds)
DEFAULT
1 - 99 # (Another time in seconds)
1
2
PRESS * TO EXIT PROGRAMMING
DELETE USERS BY CARD
2
<BADGE CARD>
1
2
THSI METHOD REQUIRES EXISTING CARD TO BE PRESENT
PRESS * TO EXIT PROGRAMMING
ADD CARD USERS WITH MANAGER CARDS
<BADGE MANAGER ADD CARD>
<BADGE USER CARD BEING ADDED>
1
2
<BADGE MANAGER ADD CARD>
3
THIS METHOD DOES NOT REQUIRE PROGRAMMING MODE
METHOD IS IDENTICAL FOR DELETING USERS WITH MANAGER CARD
Colour Indicators refer to LED status lights on Keypad
NEPTUNE
Quick Reference Guide