background image

TSN

21286

-1 Rev.1 - Page 1

13

th October, 20

21

NEPTUNE KEYPAD TOUCH EM/HID

/MF

 S/ALONE or WIEGAND IP65 (2x6)

 

MODELS

NEKPWST2S

PROGRAMMING

ENTER PROGRAMMING MODE

*

<MASTER CODE> #

  (

default 888888

)

CHANGE MASTER CODE

0

<NEW MASTER CODE> # <REPEAT> #

ADD PIN USERS

1

<USER NUMBER (1-2000)> #

<PIN NUMBER> #

1

2

3

1

2

MASTER CODE MUST BE BETWEEN 6-8 DIGITS.

PRESS * TO EXIT PROGRAMMING

ADDITIONAL USERS CAN BE ADDED BY REPEATING STEPS 2 & 3

EXAMPLE

1 1 # 9384 # 2 # 2958 # 3 # 9876 # *

The programming above added 3 users with unique pin numbers

PIN NUMBERS MUST BE BETWEEN 4-6 DIGITS

PRESS * TO EXIT PROGRAMMING

ADD CARD USERS

1

<USER NUMBER (1-2000)> #

<BADGE CARD>

1

2

3

ADDITIONAL USERS CAN BE ADDED BY REPEATING STEPS 2 & 3

EXAMPLE

1 1 # <BADGE CARD> 2 # <BADGE CARD> *

The programming above added 2 users with cards

THE ABOVE METHOD IS PREFERRED FOR CARD PROGRAMMING

SO INSTALLERS CAN NOTE WHICH USER NUMBER EACH CARD

IS ASSIGNED TO.

PRESS * TO EXIT PROGRAMMING

DELETE USERS BY USER NUMBER

2

<USER NUMBER (1-2000)> #

1

2

ALL USERS CAN BE DELETED USING THE FOLLOWING STEPS

PIN NUMBERS MUST BE BETWEEN 4-6 DIGITS

PRESS * TO EXIT PROGRAMMING

2

0000 #

1

2

SET DOOR RELAY TIME

4

0 # (50ms / 5 seconds) 

DEFAULT

1 - 99 # (Another time in seconds)

1

2

PRESS * TO EXIT PROGRAMMING

DELETE USERS BY CARD

2

<BADGE CARD>

1

2

THSI METHOD REQUIRES EXISTING CARD TO BE PRESENT

PRESS * TO EXIT PROGRAMMING

ADD CARD USERS WITH MANAGER CARDS

<BADGE MANAGER ADD CARD>

<BADGE USER CARD BEING ADDED>

1

2

<BADGE MANAGER ADD CARD>

3

THIS METHOD DOES NOT REQUIRE PROGRAMMING MODE

METHOD IS IDENTICAL FOR DELETING USERS WITH MANAGER CARD

Colour Indicators refer to LED status lights on Keypad

NEPTUNE 

Quick Reference Guide

Reviews: