background image

 
 

Adding the Keypad to the System – Network Inclusion 

Add

 

the

 

keypad

 

device

 

to

 

the

 

Vivint

 

system

 

using

 

one

 

of

 

the

 

following

 

methods:

  

This

 

product

 

can

 

be

 

operated

 

in

 

any

 

Z

Wave

 

network

 

with

 

other

 

Z

Wave

 

certified

 

devices

 

from

 

other

 

manufacturers.

 

All

 

mains

 

operated

 

nodes

 

within

 

the

 

network

 

will

 

act

 

as

 

repeaters

 

regardless

 

of

 

vendor

 

to

 

increase

 

reliability

 

of

 

the

 

network.

 

A

 

S2

 

security

 

enabled

 

controller

 

is

 

required

 

to

 

operate

 

the

 

product.

 

 

Vivint

 

app

 

(SmartStart):

 

Scan

 

the

 

SmartStart

 

QR

 

code

 

on

 

the

 

box

 

with

 

your

 

smartphone,

 

and

 

then

 

follow

 

the

 

prompts

 

in

 

the

 

app.

 

(Note:

 

The

 

QR

 

code

 

can

 

also

 

be

 

found

 

inside

 

the

 

battery

 

cover

 

under

 

the

 

batteries.)

 

SmartStart

 

enabled

 

products

 

can

 

be

 

added

 

into

 

a

 

Z

Wave

 

network

 

by

 

scanning

 

the

 

Z

Wave

 

QR

 

Code

 

present

 

on

 

the

 

product

 

with

 

a

 

controller

 

providing

 

SmartStart

 

inclusion.

 

No

 

further

 

action

 

is

 

required

 

and

 

the

 

SmartStart

 

product

 

will

 

be

 

added

 

automatically

 

within

 

10

 

minutes

 

of

 

being

 

switched

 

on

 

in

 

the

 

network

 

vicinity.

 

 

Vivint

 

panel/hub

 

via

 

Z

Wave

 

(Classic

 

Inclusion):

 

Use

 

this

 

standard

 

method

 

for

 

adding

 

Z

Wave

 

devices

 

at

 

the

 

panel

 

or

 

hub.

 

Use

 

the

 

"PAIR/RESET"

 

button

 

next

 

to

 

the

 

battery

 

tray.

 

Follow

 

the

 

onscreen

 

prompts

 

to

 

add

 

the

 

keypad.

 

Installation Instructions  

You

 

can

 

install

 

(mount)

 

the

 

keypad

 

with

 

either

 

screws

 

or

 

tape:

 

1.

 

To

 

mount

 

with

 

the

 

provided

 

screws

:

  

a.

 

Slide

 

the

 

battery

 

cover

 

/

 

mounting

 

plate

 

down

 

and

 

remove

 

it.

 

b.

 

Place

 

the

 

mounting

 

plate

 

in

 

the

 

desired

 

location.

 

c.

 

Secure

 

the

 

mounting

 

plate

 

with

 

the

 

2

 

screws,

 

using

 

the

 

slotted

 

hole

 

to

 

adjust

 

the

 

plate

 

up

 

or

 

down

 

to

 

ensure

 

a

 

precise

 

level.

 

d.

 

Reattach

 

the

 

keypad

 

by

 

placing

 

it

 

directly

 

on

 

the

 

mounting

 

plate,

 

and

 

sliding

 

it

 

down

 

until

 

it

 

locks

 

into

 

place.

 

2.

 

To

 

mount

 

with

 

tape

:

  

a.

 

Remove

 

the

 

tape's

 

backing

 

paper

 

from

 

back

 

of

 

the

 

mounting

 

plate

 

(do

 

not

 

remove

 

the

 

plate

 

itself).

 

b.

 

Place

 

the

 

keypad

 

in

 

the

 

desired

 

location,

 

being

 

careful

 

to

 

ensure

 

a

 

precise

 

level.

 

c.

 

Press

 

the

 

keypad

 

against

 

the

 

wall

 

for

 

30

 

seconds

 

to

 

activate

 

the

 

tape

 

and

 

secure

 

it

 

to

 

the

 

wall.

 

3.

 

Once

 

installed,

 

enable

 

the

 

batteries

 

by

 

removing

 

the

 

pull

 

tab.

 

4931

 

N

 

300

 

W

 

Provo,

 

UT

 

84604

 
 

 

The

 

Vivint

 

Keypad

 

is

 

a

 

wireless

 

Z

Wave

TM

 

control

 

device

 

that

 

provides

 

remote

  

access

 

to

 

the

 

security

 

features

 

for

 

a

 

Vivint

 

Smart

 

Home™

 

system,

 

including

  

enabling

 

and

 

disabling

 

both

 

the

 

Arm

 

Away

 

and

 

Arm

 

Stay

 

security

 

modes.

 

The

 

keypad

 

can

 

also

 

be

 

used

 

to

 

transmit

 

a

 

signal

 

to

 

Vivint

 

Monitoring

 

for

 

fire,

 

panic,

  

and

 

general

 

emergency

 

conditions

 

such

 

as

 

a

 

home

 

intrusion.

  

The

 

keypad

 

has

 

an

 

easy

to

use

 

interface

 

with

 

identified

 

and

 

illuminated

 

buttons,

  

as

 

well

 

as

 

indicator

 

icons

 

that

 

show

 

when

 

the

 

device

 

is

 

offline,

 

or

 

battery

  

power

 

is

 

low.

 

It

 

also

 

displays

 

security

 

system

 

status

 

with

 

a

 

downcast

 

light.

 

This

 

document

 

includes

 

a

 

product

 

description,

 

installation

 

instructions,

 

basic

 

operation,

 

illustrations,

 

technical

 

specifications,

 

and

 

regulatory

 

references.

 

Basic Operation / User Functionality 

Once

 

the

 

keypad

 

is

 

up

 

and

 

running,

 

the

 

user

 

can

 

perform

 

the

 

following

 

functions.

 

For

 

more

 

details,

 

refer

 

to

 

online

 

Help

 

at

  

the

 

Vivint

 

Support

 

site:

 

support.vivint.com

.

 

 

MAIN

 

FEATURES

 

  

 

Arm

 

to

 

STAY

 

mode

 

(press

 

&

 

hold

 

the

 

button

 

for

 

3

 

seconds)

 

 

Arm

 

to

 

AWAY

 

mode

 

(press

 

&

 

hold

 

the

 

button

 

for

 

3

 

seconds)

 

 

Disarm

 

the

 

system

 

(enter

 

a

 

valid

 

user's

 

4

digit

 

PIN

 

code)

 

 

Send

 

an

 

emergency

 

signal

 

to

 

Vivint

 

Monitoring

 

(press

  

the

 

PANIC,

 

FIRE,

 

or

 

EMERGENCY

 

button

 

for

 

2

 

seconds)

 

 

Verify

 

system

 

status

 

(wake

 

the

 

keypad

 

by

 

touching

 

it,

  

and

 

view

 

the

 

downcast

 

light)

 

as

 

indicated

 

by

 

these

 

colors:

 

     

Green

:

 

System

 

disarmed

 

     

Orange

:

 

System

 

armed

 

     

Red

:

 

Alarm

 

in

 

progress

 

Quick

 

Reference

 

(User

 

Manual

 

 

Install

 

&

 

Operation)

 

Keypad

 

(front

 

view)

 

 

Vivint Keypad 

(VS-KPAD01-001)

 

 

 

Keypad

 

(back

 

view,

 

open;

  

battery

 

cover

 

/

 

mounting

 

plate

 

off)

 

 

Summary of Contents for VS-KPAD01-001

Page 1: ...ng paper from back of the mounting plate do not remove the plate itself b Place the keypad in the desired location being careful to ensure a precise level c Press the keypad against the wall for 30 seconds to activate the tape and secure it to the wall 3 Once installed enable the batteries by removing the pull tab 4931 N 300 W Provo UT 84604 The Vivint Keypad is a wireless Z WaveTM control device ...

Page 2: ...ations However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the sep...

Page 3: ...fic device class of SPECIFIC_TYPE_SECURE_KEYPAD 0x0B Manufacturer Specific Manufacturer ID 0x0156 Product Type 0x4B50 Product ID 0x0001 Association The keypad supports one Association group which is the Lifeline group of able to have one node in the group All unsolicited Z Wave messages are transmitted to the node in the Lifeline group such as Entry Control Notification Battery and Device Reset Lo...

Page 4: ...numerated Read only No Min Value 0 Max Value 1 Default Value 1 3 Down Cast Light Description Enable the down cast light 1 Enabled default 0 Disabled Size 1 Format Enumerated Read only No Min Value 0 Max Value 1 Default Value 1 4 Application Level Retries Description Number of attempts on top of the stack level retries to try to reach the controller hub with Z Wave messages Size 1 Format Unsigned I...

Page 5: ...e On Off Period and On Off Cycles can safely interrupt the other indicators and the other indicators if active will resume The Armed Indicator is ignored if it has not previously received an Armed Away or Armed Stay Indicator The Identify indicator flashes the device s backlight keys Entry Control The Keypad uses the Entry Control command class to communicate the button presses of keypad The Away ...

Page 6: ... all unsolicited Z Wave messages from the Keypad to the controller are encapsulated in a Supervision Get command to ensure proper decoding so the Keypad must see both an ACK and a corresponding Supervision Report to consider the message communicated successfully Z Wave Certification This product is Z Wave certified The Z Wave Certification is ZCXX XXXXXXX For more information please visit www z wa...

Reviews: