Vivint VS-KPAD01-001 Quick Reference Download Page 4

 
 

 
 
 

 

©

 

2021

 

Vivint

 

Inc.

 

All

 

Rights

 

Reserved.

   

|

   

1

800

216

5232

   

|

   

M/N:

 

KP01

   

|

   

Doc

 

P/N:

 

77

600046

001

 

Rev.

 

1.0

 

Configuration  

The

 

keypad

 

supports

 

five

 

configuration

 

parameters

 

listed

 

below.

 

1.

 

Motion

 

Detector

 

Description

 

Whether

 

or

 

not

 

motion

 

detector

 

is

 

enabled.

 

1:

 

Enabled

 

(default)

 

/

 

0:

 

Disabled.

 

Size

  

1

 

Format

 

Enumerated

 

Read

 

only

 

No

 

Min

 

Value

 

0

 

Max

 

Value

 

1

 

Default

 

Value

 

1

 

 

2.

 

Sound

 

Description

 

Enable

 

beeper

 

feedback.

 

1:

 

Enabled

 

(default)

 

/

 

0:

 

Disabled.

 

Size

  

1

 

Format

 

Enumerated

 

Read

 

only

 

No

 

Min

 

Value

 

0

 

Max

 

Value

 

1

 

Default

 

Value

 

1

 

 

3.

 

Down

Cast

 

Light

 

Description

 

Enable

 

the

 

down

cast

 

light.

 

1:

 

Enabled

 

(default)

 

/

 

0:

 

Disabled.

 

Size

  

1

 

Format

 

Enumerated

 

Read

 

only

 

No

 

Min

 

Value

 

0

 

Max

 

Value

 

1

 

Default

 

Value

 

1

 

 

4.

 

Application

Level

 

Retries

 

Description

 

Number

 

of

 

attempts

 

on

 

top

 

of

 

the

 

stack

level

 

retries

 

to

 

try

 

to

 

reach

 

the

 

controller/hub

 

with

 

Z

Wave

 

messages.

 

Size

  

1

 

Format

 

Unsigned

 

Integer

 

Read

 

only

 

No

 

Min

 

Value

 

0

 

Max

 

Value

 

10

 

Default

 

Value

 

3

 

 

5.

 

Battery

Poll

 

Timer

 

Description

 

Amount

 

of

 

time

 

in

 

minutes

 

between

 

timed

 

battery

 

checks.

 

Size

  

2

 

Format

 

Unsigned

 

Integer

 

Read

 

only

 

No

 

Min

 

Value

 

5

 

Max

 

Value

 

1440

 

Default

 

Value

 

70

 

 

Summary of Contents for VS-KPAD01-001

Page 1: ...ng paper from back of the mounting plate do not remove the plate itself b Place the keypad in the desired location being careful to ensure a precise level c Press the keypad against the wall for 30 seconds to activate the tape and secure it to the wall 3 Once installed enable the batteries by removing the pull tab 4931 N 300 W Provo UT 84604 The Vivint Keypad is a wireless Z WaveTM control device ...

Page 2: ...ations However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the sep...

Page 3: ...fic device class of SPECIFIC_TYPE_SECURE_KEYPAD 0x0B Manufacturer Specific Manufacturer ID 0x0156 Product Type 0x4B50 Product ID 0x0001 Association The keypad supports one Association group which is the Lifeline group of able to have one node in the group All unsolicited Z Wave messages are transmitted to the node in the Lifeline group such as Entry Control Notification Battery and Device Reset Lo...

Page 4: ...numerated Read only No Min Value 0 Max Value 1 Default Value 1 3 Down Cast Light Description Enable the down cast light 1 Enabled default 0 Disabled Size 1 Format Enumerated Read only No Min Value 0 Max Value 1 Default Value 1 4 Application Level Retries Description Number of attempts on top of the stack level retries to try to reach the controller hub with Z Wave messages Size 1 Format Unsigned I...

Page 5: ...e On Off Period and On Off Cycles can safely interrupt the other indicators and the other indicators if active will resume The Armed Indicator is ignored if it has not previously received an Armed Away or Armed Stay Indicator The Identify indicator flashes the device s backlight keys Entry Control The Keypad uses the Entry Control command class to communicate the button presses of keypad The Away ...

Page 6: ... all unsolicited Z Wave messages from the Keypad to the controller are encapsulated in a Supervision Get command to ensure proper decoding so the Keypad must see both an ACK and a corresponding Supervision Report to consider the message communicated successfully Z Wave Certification This product is Z Wave certified The Z Wave Certification is ZCXX XXXXXXX For more information please visit www z wa...

Reviews: