background image

 

Security Keypad Z-Wave

TM

 700 

Quick Start Guide

 

V1.0 

Model: 7BA-KP-V-B-C0   

 

 

 

 

 

 

 

 

Summary of Contents for Z-Wave 700 7BA-KP-V-B-C0

Page 1: ...Security Keypad Z WaveTM 700 Quick Start Guide V1 0 Model 7BA KP V B C0 ...

Page 2: ...tteries Do not allow children to install batteries unsupervised Follow battery manufacturer s instructions as to proper handling storage and disposal of batteries IMPORTANT Do not expose to rain This product contains small parts and is not suitable for children Periodically check the condition of the batteries CAUTION Correct Disposal of this product This marking indicates that this product should...

Page 3: ...2 CR123A batteries 2 pre installed 3 Bracket 1 4 Installation kit a screw 2 wall anchor 2 b double sided adhesive tape 1 c reset pin 1 5 Quick start guide 1 ...

Page 4: ...nvenient user interface to arm or disarm the security system with a PIN code 3 1 Components Number pad Battery indicator Cancel Faulted sensors indicator bypass Disarm Arm stay Arm away Emergency Network indicator Speaker Approaching Sensor Confirm ...

Page 5: ...N for 2 seconds after device power on Buzzer beeps 1 times LED light on sequency First network battery faulted sensor Indicator LED light on red and turn to green then disarm green arm stay blue arm away blue SOS red LED on finally 0 9 confirm delete white backlight on totally it takes about 2 seconds after device power on Buzzer long beeps 1 time Not in the network Indicator LED and backlight wil...

Page 6: ...rning mode see Z Wave network controller operating manual 2 Trigger this action 3 Network green LED will flashing at every 1 second to indicate that the inclusion is working and solid green LED 3 seconds for indicate the inclusion is successful otherwise the LED will be soild yellow in which you need to repeat the process from step 2 Remove the Keypad from a Z Wave network 1 Set the Z Wave network...

Page 7: ...ong beep one time short beep twice in 1 5 seconds Beep Beep beep Arm Stay Blinking blue Press correct pin code then press arm stay button exit delay ongoing Count down default is 10 seconds user can set count down timing by APP Meanwhile gateway could also have beeps 10 seconds It will be set by ABUS But to save keypad power if user set count time is 30 seconds the keypad will max beep 10 seconds ...

Page 8: ... icon shows Green indicate the battery capacity is more than 10 When approaching sensor is activated the battery icon shows solid yellow indicate the battery capacity is around 10 15 When approaching sensor is activated the battery icon shows blinking yellow indicate the battery capacity is below 10 10 means user could use keypad about one weeks Faulted Sensor Indicator Solid yellow There are one ...

Page 9: ... Arm away Disarm the system by press the mode button followed by your PIN code and press the confirm button The PIN code is consisted of 6 digits and can be modified in the App Press the Emergency button and hold for 3 seconds and release to send a panic signal Deactivate a panic event by pressing the disarm button followed by your PIN code Faulted sensor If there is a faulted sensor when arming t...

Page 10: ...nd all the LED will be on for a moment with 2 beeps Then the reset is done After reset it will start to search and join the hub again 6 Mount the keypad on the wall Prior to installing on the wall please perform arming and disarming operation at the location where you decide to mount the keypad to make sure the wireless signal is good The mounting location should be somewhat near the door you usua...

Page 11: ...eries When the battery is low the battery LED will be red and you will receive a notification in your App to remind you the battery change Please do as follows Step 1 Disarm the system and remove the keypad from the bracket Step 2 Because the tamper switch is triggered you will need to disarm the system to stop the countdown Step 3 Open the battery compartment cover and remove the old batteries an...

Page 12: ...rty responsible for compliance could void the user s authority to operate the equipment Hereby Corporation declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2014 53 EU Special Rule Of Each Command Class Z Wave Plus Info Report Command Class Parameter Value Z Wave Plus Version 0x02 Role Type 0x07 ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLA...

Page 13: ...CE_RESET_LOCALLY 0x5A Command DEVICE_RESET_LOCALLY_NOTIFICATION 0x01 Notification Commands Notification Type Notification Event HOME_SECURITY 0x07 0x00 NO_EVENT 0x03 TAMPERING_COVERING_REMOVED 0x08 MOTION_DETECTION_UNKNOWN_LOCATION Manufacturer Specific Report Parameter Value Manufacturer ID 1 0x04 Manufacturer ID 2 0x03 Product Type ID 1 0x00 Product Type ID 2 0x04 Product ID 1 0x00 Product ID 2 ...

Page 14: ...on off Proximity Sensor Turn on 1 Turn off 0 3 0x03 1 0x01 1 0x01 0 0x00 1 NOT Read only UNSIGNED_I NTEGER Will alters capabilities PS Timeout The wait time of PS for clear the motion 4 0x04 5 0x05 30 0x1E 2 0x02 1 NOT Read only UNSIGNED_I NTEGER Will alters capabilities PS Sensitivity The sensitivity of PS 5 0x05 9 0x09 31 0x1F 4 0x04 1 NOT Read only UNSIGNED_I NTEGER Will alters capabilities L S...

Page 15: ... the mode button is triggered 3 Battery Report Keypad will send Battery Report when the battery level is low and the battery report s value is 0xFF 4 Device Reset Locally Notification Firmware Update Meta Data Target Description 0 ZGM130S Action System Response Keypad receives update Network LED Blink Green Keypad processing update Network LED Blink Green Switch tone Turn on 1 Turn off 0 0x08 0x01...

Page 16: ...Update complete Network LED Solid Green for 3s ...

Page 17: ...ue 0xFF to fit 16 byte blocks when sent in a notification Event Type Event Type Button label Description 0x00 Caching CACHING KEYS is sent when the user has started entering credentials 0x01 Cached CACHED_KEYS is sent when the cache size or the cache timeout is exceeded 0x02 ENTER Keypad will sent entry control notification event type 0x02 when the button is pressed 0x03 DISARM_ALL Keypad will sen...

Page 18: ...is pressed 0x12 ALERT_PANIC Keypad will sent entry control notification event type 0x12 when the SOS button is pressed 0x19 CANCEL Keypad will sent entry control notification event type 0x19 when the x button is pressed ...

Page 19: ...rming is an alarm type identifier that enables the keypad to indicate which alarm event the system has detected Defined Alarming Status Modifier Status Modifier for Armed Stay Armed Away Disarmed Bypass Challenge and Input Reject is a field that defines if the keypad should play sound and if the keypad should light up upon receiving status The modifier is a bit encoded field with 0x0 Sound ON and ...

Page 20: ...Status States Description System response 0x01 Disarmed Disarm Mode LED Icon solid GREEN Speaker short beep twice in 1 seconds ...

Page 21: ...ed Values Indicator Get Indicator Report System Mode 00 NULL Power On 03 Stay Mode 02 Away Mode 01 Disarm Mode Notification Command Class 1 Notification Supported Report 1 1 Keypad supports Home Security 0x07 2 Event Supported Report 1 1 Home Security 0x07 Motion detection 0x08 TAMPERING_COVERING_REMOVED 0x03 State idle 0x00 3 How to trigger the different notifications 1 1 Home Security 0x07 Tampe...

Reviews: