Image File Downloading Configuration
Page 3-41
Current Settings
Table 3-12 describes the settings shown in the X/Y/Z Modem Image File
Downloading Menu.
Table 3-12 X/Y/Z Modem Image File Downloading settings
Performing a Software Upgrade
Use the following procedure to upgrade the IntraCore 6524 software through
its serial (console) port.
1
In the Image File Download Configuration Menu, type x to
open the X/Y/Z Modem Image File Downloading Menu.
2
Type x, y, or z to select the corresponding modem protocol.
◆
Note: For information about these protocols, see the
manual for your communications software.
3
Type c to select the console baud rate. The Baud Rate Set-
ting Menu appears, as shown in Figure 3-20. The maximum
baud rate currently supported is 57,600 bps.
Setting
Description
Bank 1 Image Version/
Date
The version number and compilation date of runtime code that is
stored in memory Bank 1 on the IntraCore 6524.
Bank 2 Image Version/
Date
The version number and compilation date of runtime code that is
stored in memory Bank 2 on the IntraCore 6524.The (Running)
designation indicates that the runtime code is currently running
on this Bank.
Download Protocol
Current setting of the IntraCore 6524’s serial download protocol.
Current Baud Rate
Transmission rate for the IntraCore 6524’s serial port.
Destination Bank
Number of the memory bank where the image file will download.