Chassis Installation/Placement
Page 2-3
Chassis Installation/Placement
The IntraCore 6524 can be installed in a standard 19-inch equipment rack. It
can also be placed on a stable horizontal surface.
▲
The equipment rack or desk on which you install your
IntraCore 6524
must
be secure and stable. Equipment racks
must be fastened to the floor; desks must be resting on a
flat, stable surface.
Installation in an Equipment Rack
To install the unit in an equipment rack, use the following procedure:
Safety Precautions for Rack Installation
▲
Important!
Before continuing, disconnect all cables from
the IntraCore 6524.
Equipment Rack Guidelines
Table 2-2 Equipment Rack Guidelines
Guideline
Specification
Size
Width; 17.75 inches (45.1 cm).
Depth: 19.25 inches (48.9 cm) to 32 inches (81.3 cm).
Ventilation
Ensure that the rack is installed in a room where the temperature remains
below 40° C (104° F). Ensure also that there are no obstructions, such as
other equipment or cables, blocking airflow to or from the IntraCore 6524
vents.
Clearance
In addition to providing clearance for ventilation, ensure that there is ade-
quate clearance for servicing the IntraCore 6524 from the front.