Model 8640B
TM 9-4935-601-14-7&P
Table 1-2. Recommended Test Equipment (3 of 7)
Instrument Type
Critical Specifications
Suggested Model
Use*
With Filter Kit
Output Low Pass Filters for FM Dis-
With HP
P,A
criminator (20 kHz and 1 MHz
10531A
Butterworth filters)
600 Ohm Feedthrough
Impedance: 6002 ± 1% shunt
HP 11095A
P,A
Connectors: BNC
520 MHz Notch
Notch Frequency Accuracy:
HP 08640-60502
P
Filter
500 - 540 MHz
Notch Rejection: >60 dB
See Figure 1-7
4 MHz Low Pass Filter
4 MHz low pass (3 pole)
CIR-Q-TEL
P,A
(2 required)
Impedance: 50
Ω
FLT/21B-4-3/
VSWR: <1.5:1
50-3A/3B
Ripple: <±0.2 dB
1.5 MHz Low Pass
1.5 MHz low pass (3 pole)
CIR-Q-TEL
P,A
Filter
Impedance: 50
Ω
FLT/21B-
VSWR: <1.5:1
1500K-3/50-
Ripple: <±0.2 dB
3A/3B
15 kHz Low Pass
15 kHz low pass (7 pole)
CIR-Q-TEL
P
Filter
Impedance: 50
Ω
FLT/21B-15K-
Ripple: <±0.2 dB
7/50-3A/3B
3 kHz Low Pass
3 kHz low pass (5 pole)
CIR-Q-TEL
P
Filter
Impedance: 50
Ω
FLT/21B-3K-
Ripple: <±0.2 dB
5/50-3A/3B
Frequency Counter
Range: to 550 MHz
HP 5327C
P,A,T
Input Sensitivity: <100 mV
Inputs: 50
Ω
and high impedance
(1 M
Ω
)
Standard Reference Accuracy:
<3 x 10
-
7
/month aging rate
<5 x 10
-
9
/s rms short term
stability
<±2.5 x 10
-6
, 0 - 50°C temper-
ature stability
Optional Reference Accuracy:
Option H49
P
<3 x 10
-9
/day aging rate
<1 x 10
-10
/s rms short term
stability
<1 x 10
-8
, 0 - 50°C temper-
ature stability
*P = Performance; A = Adjustments; T = Troubleshooting
1-15