Model 8640B
TM 9-4935-601-14-7&P
MANUAL CHANGES
CHANGE M (cont'd)
Service Sheet 7 (schematic)
Change to read as follows:
A7R13
4640
Ω
A7R30
46.4
Ω
A7R45
14.7K
A7R54
6810
Ω
A7R21
133
Ω
A7R31
46.4
Ω
A7R46
8250
Ω
A7R57
110
Ω
A7R22
562
Ω
A7R32
46.4
Ω
A7R47
7500
Ω
A7R58
100
Ω
A7R23
1960
Ω
A7R33
46.4
Ω
A7R48
6810
Ω
A7R59
90.9
Ω
A7R24
3160
Ω
A7R34
46.4
Ω
A7R49
6190
Ω
A7R60
82.5
Ω
A7R25
4220
Ω
A7R35
46.4
Ω
A7R50
5620
Ω
A7R61
75.0
Ω
A7R26
5110
Ω
A7R36
46.4
Ω
A7R51
5110
Ω
A7R62
68.1
Ω
A7R27
6190
Ω
A7R37
31.6
Ω
A7R52
4640
Ω
A7R63
61.9
Ω
A7R28
6810
Ω
A7R40
6810
Ω
A7R53
5620
Ω
A7R64
56.2
Ω
A7R65
51.1
Ω
Service Sheet 9A (schematic):
Change AllR34 to 5110Q2.
Change AllR35 to 1000Q2.
CHANGE N
NOTE
See paragraph 7-56 for recommended instrument modification.
Page 5-2, Table 5-1:
Delete A10OA2R6-8, R12-14, and R18-20.
Pages 5-2 and 5-3, paragraph 5-21:
Delete sections b. and c. A10OA2R6-8, R12-14, and R18-20.
Page 6-17, Table 6-3:
Change A8A4R3 to 0757-0458 RESISTOR; FXD; 51.1K OHM ±1% 1/8W.
Delete A8A4R5.
Delete A8A4XDSlA/B.
Page 6-38, Table 6-3:
Change C6 to 0160-0586 CAPACITOR; FXD; 0.022 UF + 20% 100 WVDC.
Service Sheet 20 (schematic):
Delete A8A4R5.
7-24
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com