![Artesyn Embedded Technology MVME8100 Installation And Use Manual Download Page 48](http://html.mh-extra.com/html/artesyn-embedded-technology/mvme8100/mvme8100_installation-and-use-manual_2977746048.webp)
Hardware Preparation and Installation
MVME8100 / MVME8110 Installation and Use (6806800P25J
)
48
6. Slide the RTM into the chassis until resistance is felt.
7. Simultaneously move the injector/ejector levers in an inward direction.
8. Verify that the RTM is properly seated and secure it to the chassis using the two
screws located adjacent to the injector/ejector levers.
9. Connect the appropriate cables to the RTM.
Removal Procedure
1. Turn off the power.
2. Disconnect all the cables.
3. Loosen and remove the screws located adjacent to the injector/ejector levers that
securing board to the chassis.
4. Move the injector/ejector levers in an outward direction.
5. Hold top and bottom edges of the board and exert minimal force when pulling the
board from the chassis to prevent pin damage.
6. Remove the transition module from the chassis and insert the filler panels.
2.4.2
PMC/XMC Installation
The PMC connectors are placed to support two single-width PMCs or one double-width PMC.
PMC site 1 supports front PMC I/O and rear PMC I/O via the Jn4 connector. PMC 1 I/O is routed
to the VME P2 connector. PMC site 2 only supports front PMC I/O and does not have a Jn4
connector. The PMC 1 Jn4 user I/O signals only support low-current high-speed signals and
thus do not support current-bearing power supply usage.
The user-configured switches are accessible with the PMC/XMCs installed. The onboard PMC
sites are configured to s3.3 V I/O PMC modules. The onboard PMC sites do not
s5.0 V I/O PMC modules.
The MVME8100 ENP4 version only supports rugged conduction cooled PMC/XMC modules
(see VITA 20-2001 for conduction cooled PMC for mechanical definition.
Follow the steps to install a PMC/XMC module onto the MVME8100 / MVME8110 board.
Summary of Contents for MVME8100
Page 1: ...MVME8100 MVME8110 Installation and Use P N 6806800P25J August 2015 ...
Page 8: ...MVME8100 MVME8110 Installation and Use 6806800P25J 8 List of Tables ...
Page 10: ...MVME8100 MVME8110 Installation and Use 6806800P25J 10 List of Figures ...
Page 26: ...MVME8100 MVME8110 Installation and Use 6806800P25J Sicherheitshinweise 26 ...
Page 58: ...Hardware Preparation and Installation MVME8100 MVME8110 Installation and Use 6806800P25J 58 ...
Page 84: ...Connectors LEDs and Switches MVME8100 MVME8110 Installation and Use 6806800P25J 84 ...
Page 108: ...Functional Description MVME8100 MVME8110 Installation and Use 6806800P25J 108 ...
Page 122: ...Related Documentation MVME8100 MVME8110 Installation and Use 6806800P25J 122 ...
Page 123: ......