Functional Description
MVME8100 / MVME8110 Installation and Use (6806800P25J
)
100
Status and Control registers
Miscellaneous control logics
Watchdog timer
32-bit Tick Timers
Clock generator
Switch decoder and LED controller
4.19 Power Management
The 5 volt coming from the back plane is utilized to derive all on-board voltage rails. To provide
the required voltage sequencing, each voltage rail is controlled by the CPLD through enable pin
of each regulator and the output is being monitored by CPLD through each regulator power
good signal. If one voltage rail fails, the CPLD will disable all of the regulators and the only way
to restart the board is by power cycling the chassis 5 volt power.