Atlanta
English
05060191 00 06-2021
17
20. 6 Clean the stainless steel
Certain situations can cause the formation of rust on the surfaces in steel, such as:
iron remains left on damp surfaces, limestone, chlorine or ammonia based detergents not rinsed
properly, food incrustations or residues, salt-saline solutions, dry residues of evaporated liquids.
Remedy
recent stains and rust:
clean with shampoo or neutral detergents, using a sponge or a rag.
When finished, eliminate any detergent residue, rinsing abundantly and thoroughly
drying the surfaces.
old stains and rust:
use chemical substances on the stainless steel that contain 25% of nitric acid or similar
substances.
persistent stains and rust:
sand with a stainless steel brush, wash with detergent and dry thoroughly.
This intervention may however cause scratches to the surfaces due to the
abrasive cleaning method. DO NOT use hydrochloric acid on stainless steel
surfaces
CAUTION
! Slippery floor. Falling.
Remove from the floor any items such as sponges, rags, waste of water or detergent.
Carefully remove all detergent residues.
i
Carefully follow the sanitizing, rinsing and drying procedures to prevent proliferation of
harmful bacteria.
20. 7
Inspect the parts
Once the sanitising, rinsing and drying operations are complete, proceed as follows:
Step
Action
1
check that all parts are perfectly clean and dry
2
check that they are not damaged or too worn
3
replace worn parts with new identical parts supplied only by the manufacturer
4
install the parts perfectly dry
5
restore electrical power supply
Once the internal operating temperature has been reached, it is possible to load the products.
21.
Load the refrigerant
DANGER! Coolant gas. Explosion. Asphyxia, alteration of cardiac pace, frostbite, anaes
-
thetic effects.
BEFORE ANY OPERATION EMPTY THE ENTIRE SYSTEM!
WARNING! FIRE. Burns. Asphyxia
NEVER use naked flames and electrical tools next to gas
Only specialist technicians may recharge the refrigerant or work on the gas circuit according
to the European Regulation 517/2014
Check that refrigerant circuit is perfectly sealed
Only use original approved spare parts
i
To fill with refrigerant, refer to system user’s manual.