Atlanta
English
05060191 00 06-2021
12
Liability
Customer
provide a power line to the cabinet connection point.
Installer
provide the anchoring devices for all the wires in input and out-
put to/from the cabinet.
Manufac
-
turer
ARNEG S.p.A. denies all liability with respect to the user or third
parties for:
- damage caused by malfunctions of the systems placed up-
stream of the cabinet
- damage caused to the cabinet by malfunctions of the electri-
cal system.
Power
supply line
•
the supply lines of the electric energy should meet the requirements of power
consumption of the cabinet chap.9.
•
check that the power line:
- has wires with suitable cross section
- is protected against over-current, overload and dispersions toward earth in
accordance with the rules in force
- for power lines longer than 4-5 m use cables with suitable cross-section.
i
The replacement of the damaged power cord is reserved to the manu
-
facturer or a body authorised by the same.
Automatic
safety switches
DANGER! Live parts. Short circuit. Electrocution
The automatic circuit breaker must be such that they do not open the
circuit on the neutral, without simultaneously opening on the phases
and, in any case, must allow complete disconnection in conditions of
category III overvoltage.
•
protect upstream cabinets with omnipolar circuit breakers with suitable char-
acteristics that will also function as master switches to section off the line
•
inform the operator of the position of the switches so that they can be reached
immediately in the event of an EMERGENCY.
Before
connecting
DANGER! Live parts. Short circuit. Electrocution
Check that the attachments of the lighting systems (floors, roof, ceil
-
ing) are properly inserted and locked into their housings to avoid
disconnections during cleaning and maintenance operations, that may
cause harmful electric shocks.
•
consult the wiring diagrams annexed to the cabinet
•
ensure that the rating plate data matches the characteristics of the electrical
system to which the cabinet must be attached
•
check that power supply voltage is the one reported on the rating plate
•
remove all metallic objects worn: rings, watches, bracelets, earrings, etc.
•
proceed with the connection.
i
If the electrical supply is interrupted, the electrical equipment of the shop will not restart,
triggering the overload protection devices; modify the system to differentiate the start-up of
the various devices.