14.17.4 Time measuring
B-channel delay
The ARGUS setups a leased line to a remote loopbox and measures the propagation delay
for the data in the selected B-channel. If the ARGUS does not receive the data back in the
B-channel in about 13 seconds, it will display the message “No loop”.
The measurement (continuous measurement) must be terminated manually.
The ARGUS - Main menu
Enter the B-channel from the keypad (first
press
<Del.>
) or use the cursor keys to
set the B-channel.
Perform measurement
Display:
The measurement will be repeated in
cycles (continuous measurement).
avg:
average B-channel delay
min:
shortest B-channel delay
max:
longest B-channel delay
bit:
The average B-channel delay in bits
(multiples of the time required to
send a bit at 64 kbit/s, it takes 15.26
µsec to send a bit).
Terminates the measurement
and displays the results of the last
measurement
Single Tests
Time measuring
B-channel select
B-channel delay