Subject to change · V 4.06.19 · EN
Page 16
www.argo-hytos.com
Fig. 9: Oil outlet
Fig. 10: Pressure line (for operation without pump)
Fig. 11: Suction line (for operation with pump)
1 Oil outlet
This is a CPC-LC coupling with slide protection, which prevents unintended unlocking of the plug-in nipple.
In order to unplug the hose from the coupling, the slider (see arrow) must be pressed in the direction of the intake
hole.
After use, close the connection with the included sealing plug.
2 Pressure line (for operation without pump)
When the pressure in the oil suction line is sufficiently high (min. 10 bar (145 psi) / max. 320 bar (4600 psi) /
min. 50 ml/min
depending on viscosity), the oil inlet can be attached to this Minimess pressure connection (M16x2).
3 Suction line (for operation with internal pump)
After use, close the connection with the included sealing plug.