background image

Subject to change · V 4.06.19 · EN

Page 32

www.argo-hytos.com

Oil contamination

Parameters which describe the oil contamination can be selected here.

The following parameters can be selected:

Oil condition

Here, parameters can be selected which describe the oil condition.

The respective parameter can be selected using the         or         key.

Press the         button to return to the start screen menu.

Confirm the selection by pressing the         button.
This parameter, which describes the oil state, thus appears at the correspondingly selected location on the start screen.

Summary of Contents for OPCom

Page 1: ...talog specifications are no guaranteed features The information given does not release the user from his her own assessments and inspection Our products are subject to a process of natural wear and ag...

Page 2: ...ty instructions 7 3 General instructions 8 4 Scope of delivery 9 5 About this product 10 5 1 Functional description 10 5 2 Measured values 10 5 3 Component overview 11 5 4 Controls 12 5 5 Control pane...

Page 3: ...pair 37 10 1 Maintenance 37 10 2 Repair 37 10 3 Spare parts 37 11 Software 38 12 Decomissioning 39 13 Disassembly 40 14 Disposal 41 14 1 Environmental protection 41 15 Extension and conversion 42 15 1...

Page 4: ...For better understanding these are explained in the following sections 1 3 1 Safety instructions in this documentation In this documentation safety instructions are faced with a sequence of actions wh...

Page 5: ...rease the intelligibility of the documentation Symbol Meaning If this information is not observed the product cannot optimally be used or operated This symbol warns against laser beams Singular indepe...

Page 6: ...rating states can occur in the application which can cause personal injury and or material damage Therefore only use this product in safety related applications if this use is expressly specified and...

Page 7: ...nstalled in safety relevant applications unintended operating states can occur in the application which can cause personal injury and or material damage Therefore only use the product in safety releva...

Page 8: ...oreign bodies such as welding beads or metal chips from entering the hydraulic lines and leading to premature wear or malfunction Make sure that connections hydraulic lines and attachment parts e g ga...

Page 9: ...argo hytos com 4 Scope of delivery The package includes 1 OPCom Portable Oil Lab 1 Operating manual 1 Power supply 100 240 VAC 1 Power cable 1 Low pressure hose set including connection couplings 1 H...

Page 10: ...ber Variances are very precisely indicated Through continual monitoring of fluid conditions changes in the machine can be detected very quickly With quick warning measures can be taken to prevent incr...

Page 11: ...he control electronics include battery management supply connections and various measuring functions 4 Control panel In the case of an alarm this indicator lights up red Observe the instructions in th...

Page 12: ...ot 6 Oil out CPC LC 7 Pressure line Minimess M16x2 8 Suction line internal pump CPC LC 1 Power button 2 Alarm LED green 3 Alarm LED yellow 4 Alarm LED red 5 Standby indicator 6 Select previous menu it...

Page 13: ...The blue button on the top right above the printer see arrow signals the operational readiness of the printer initiates the line feed by pressing it Pull the flap in order to open the cover Then repl...

Page 14: ...rt case may be transported with a shoulder strap which can be fastened to the movable belt mounts 1 see Chapter 15 1 accessories There are no special transport notes for this product In the case of ai...

Page 15: ...ct the device to a pressure line in the off line flow by means of a T junction At the connection point constant pressure conditions should prevail The pressure may vary but pressure peaks or strong fl...

Page 16: ...om the coupling the slider see arrow must be pressed in the direction of the intake hole After use close the connection with the included sealing plug 2 Pressure line for operation without pump When t...

Page 17: ...onnected power In battery mode the cells with a total capacity of 6 900 mAh supply the necessary power They are charged by connecting a power cord to the charging connection Once the power has been co...

Page 18: ...etwork 100 240 VAC then a plug symbol is shown on the display 4 To ensure a full charge the device must be connected to the power cable for at least 1 h 5 When a charging state of 100 is reached the c...

Page 19: ...device into operation The information for intended use the operating conditions and the technical specifications must be adhered to Connect the portable Particle Monitor OPCom Portable Oil Lab to the...

Page 20: ...s To turn the device on off To confirm a selected option value To cancel the current input back Within the menu scroll up Within the menu scroll down To select next data set numerical value in menu To...

Page 21: ...lect Measurement info User menu Select user Go trough stored users Measurement short menu Start screen High pressure measurement Pump mode Automatic mode Storage short menu Print all Print short Parti...

Page 22: ...settings Select start screen Display Time date Language Edit time date Select printed info Auto print Defined types Oil contamination Oil condition Parameter row 1 Parameter row 2 Oil condition Oil c...

Page 23: ...u In case of battery operation the current charge of the battery cells is displayed with a status bar When the device is plugged in the charging sign is displayed If necessary if the bar decreases a p...

Page 24: ...ressing the or button you enter the quick menu Memory see Chapter 9 2 4 By pressing the or button you enter the Main Menu see Chapter 9 2 5 When a measuring is running By pressing the button in the st...

Page 25: ...by the symbol P in the value display A progress bar graphically displays the progress of the measurement 9 2 3 Measurement quick menu 9 2 4 Memory quick menu By pressing the or button you select the d...

Page 26: ...rement settings Measuring info menu 9 2 5 1 Memory menu After selecting this option press the button to print the displayed data set If no values are stored this display is empty In this case no furth...

Page 27: ...erature outside the measuring range 26 Humidity outside the measuring range 27 Conductivity outside the measuring range 28 Permittivity outside the measuring range 53 Incorrect temperature measurement...

Page 28: ...ushing measuring and pause times 9 2 5 2 Measurement settings Here enter the flushing time in seconds With the or button you can choose a different item With the or button you can raise or lower the v...

Page 29: ...surement the pump is switched off for the selected time before a new measurement starts Measuring info menu The measuring info menu is used to enter user defined values For max 10 measuring points a n...

Page 30: ...ective user to be edited by setting a check mark This user is then active and appears on the printout Pressing the button again allows you to name the selected user Use the or keys to select the posit...

Page 31: ...selection possibilities exist Press the button to enter the system setup menu Confirm the selection of the value line to be edited by pressing the key The following menu appears Here the selectable p...

Page 32: ...can be selected Oil condition Here parameters can be selected which describe the oil condition The respective parameter can be selected using the or key Press the button to return to the start screen...

Page 33: ...ch describes the oil state thus appears on the short print The respective value can be selected using the or key Confirm the selection by pressing the button Press the button to return to the system s...

Page 34: ...selected using the or key Press the button to return to the selection print menu Confirm the selection by pressing the button This parameter which describes the oil state thus appears on the short pri...

Page 35: ...so that the lightning switches off automatically after a certain time In addition the brightness of the lightning can be adjusted The automatic brightness setting of the display can be selected with...

Page 36: ...setup menu Here you can set the time Use the or button to select the item to be changed Use the or button to raise or lower the values takes the new value discards the new value 9 2 5 7 Time date Her...

Page 37: ...ps of the plug in connections are secure so that no humidity can penetrate into the OPCom Portable Oil Lab Clean the OPCom Portable Oil Lab only with a dry lint free tissue 10 1 Maintenance The Partic...

Page 38: ...Clight or LubMon Config can be started by double click on the LubMonPClight exe or LubMonConfig exe file Select the previously installed COM port in the settings of LubMon PClight LubMon PClight LubMo...

Page 39: ...19 EN Page 39 www argo hytos com 12 Decomissioning The Particle Monitor OPCom Portable Oil Lab is a component that does not have to be taken out of service Therefore the chapter in this guide does not...

Page 40: ...Subject to change V 4 06 19 EN Page 40 www argo hytos com 13 Disassembly This chapter does not contain any information for your device...

Page 41: ...ed to return used batteries Waste batteries may contain hazardous substances which if not properly stored or disposed of may damage the environment or human health However batteries contain different...

Page 42: ...nsion that goes beyond the conversions or extensions described here 15 1 Accessories For the Particle Monitor OPCom Portable Oil Lab you get the following accessories not included in the scope of deli...

Page 43: ...If yes which modifications Has the product machine been operated as intended How does the malfunction tend to show Form a clear idea of the cause of the problem If necessary consult the immediate ope...

Page 44: ...ver palladium sapphire PVC hoses Power supply device Power supply Power consumption 24 max 8 VDC A Power supply for the according power adaptor Power supply Power consumption Power at 24VDC output 100...

Page 45: ...Subject to change V 4 06 19 EN Page 45 www argo hytos com 17 1 Dimensional drawing Fig 16 Dimensional drawing...

Page 46: ...Subject to change V 4 06 19 EN Page 46 www argo hytos com 18 Appendix 18 1 Declaration of conformity...

Page 47: ...Republic ARGO HYTOS s r o info cz argo hytos com ARGO HYTOS Protech s r o info protech argo hytos com France ARGO HYTOS SARL info fr argo hytos com Germany ARGO HYTOS GMBH info de argo hytos com Great...