86
14.3
Error messages
diSplayed meSSage
duRation
cauSe
Remedy
Job
mode
Disable spraying command!
continue
Main switch ON upon computer switching on
• Move main switch downwards (position OFF)
--
Drive! Machine stopped
continue
Main switch ON with machine stopped
• Start the machine
• Move main switch downwards (position OFF)
MAIN ON
+
AUTO
Unable to load last job!
continue
File regarding last job is damaged
DATA FROM LAST JOB
CAN NOT BE RECOVERED
--
Map loading failed!
Select another map?
continue
Format of map to be loaded is not valid
(Par.
12.8)
or the file is damaged
Press
OK
to continue the procedure and select
another map.
--
• Press
ESC
to cancel procedure.
--
Low memory available!
delete jobs to free memory
continue
Available memory is not sufficient to save or
start a new job.
• Access the procedure to delete the jobs from
the internal memory
(par. 11.7.1)
.
--
Connection to RCU not detected!
continue
Communication problems detected between
monitor and control unit (RCU)
• Check the connection cable (and connectors)
status between monitor and control unit
(par.6.2)
--
Damaged cables
• Replace cables
--
GPS receiver not connected!
continue
Wrong connection of cable for receiver to Bravo
400
• Check connection with receiver
(par. 6.2 - 6.7)
.
--
Connection cable to receiver is damaged.
• Replace cable.
--
Receiver is damaged.
• Replace receiver.
--
Insufficient GPS signal quality!
Continue job?
continue
Position and number of satellites do not allow
for suitably accurate guidance
• Press
OK
to continue job.
Bravo 400 will output inaccurate data.
--
• Press
ESC
and wait for signal quality to
improve.
--
GPS receiver invalid data!
continue
Connecting to satellites.
• Wait for connection to be established.
--
DGPS correction not available!
Continue job?
continue
DGPS signal not present within work area.
• Press
OK
to continue job. Bravo 400 could
generate a displaying error in the guidance
screen
(par. 10.3.4)
: carry out tracks alignment
using "Align" function
(par. 13.1.7)
.
--
DGPS connection in progress.
• Press
ESC
and wait for connection to be
established: the display shows
DGPS correction not available!
Please wait...
until connection is established.
--
Stop machine!
Pump failure
continue
Pump oil level too low or mixed with water
• Stop the machine and check the pump status
--
Activate pump! Missing flowrate
continue
Main switch ON with machine stopped
but zero rate
• Start the pump and move the machine
MAIN ON
+
AUTO
Minimum tank level reached!
5 sec.
The tank level is lower than the set reserve
value
• Fill-in the tank
(par. 13.1.9)
MAIN ON
The minimum value is not set
correctly
• Check the set reserve value
(par.10.6.2)
Automatic regulation blocked!
5 sec.
The pressure does not reach the set limit
• Increase the machine speed
MAIN ON
+
AUTO
The limit has not been set correctly
• Check the set limit
(par. 11.4.2)
Decelerate! Pressure too high
continue
The pressure exceeds the maximum level
allowed for the nozzle in use
• Decrease the machine speed
• Regulate the operating pressure so as to
respect the previously set limits for nozzles in use
• Check setting of minimum pressure for the
nozzle in use
(par. 11.5.4)
MAIN ON
Accelerate! Insufficient pressure
continue
The pressure does not reach the minimum
value for the nozzle in use
• Increase the machine speed
• Regulate the operating pressure so as to
respect the previously set limits for nozzles in use
• Check setting of minimum pressure for the
nozzle in use
(par. 11.5.4)
MAIN ON
Flowmeter out of range!
5 sec.
Rate out of the limits allowed by flowmeter
• Adapt job conditions to flowmeter limits (speed,
pressure, etc...)
• Check that the flowmeter constant value has
been set correctly
(par. 10.4.3)
MAIN ON