23
10.1 - Boom settings
Fig. 40
According to the programming both the boom aspect on the display (par. 12.6) and the total length
value (near the
Boom settings
menu, Fig. 40)
10.1.1 Nozzle number
Fig. 41
Indicate the total number of nozzles on the boom.
ONLY FOR
Indicate the total number of nozzle holders fitted on the boom despite the actual number of nozzles.
For example: with 80 nozzles enter value '40'.
10.1.2 Output 1 ÷ 13
- Indicate the Bravo 400 output connection by entering the width of each boom section. Repeat the programming for each item of Fig. 40.
- Disable the disconnected. Message
Disabled
will appear on the display.
AUX
option: available for system diagnosis for ARAG personnel ONLY.
Fig. 42
Output 1
Output 2
Overall width
Fig. 43
ADVANCED PROGRAMMING - MACHINE SETTINGS
Par.
9.4
Exit
function or
datum
change
Increase /
decrease
data
Scrolling
menu
pages
Shift
the
cursor
Confirm
access or
datum
change
Reset /
disable
data
Scrolling
menu
items