57
12.3
Operating switches for control unit valves
Upon computer switching the section valves are open.
If main control is ON the message
Disable spraying command!
: no function can be accessed until main control is set again to OFF.
Main control ON
Main control OFF
Open section
Closed section
Output
increase
Output
decrease
ONLY FOR SEQUENTIAL VERSION:
Main control ON
Main control OFF
Section operating switches
Output
increase
Output
decrease
Open section
Closed section
• Switches for sequential control
a
Opens sections from the last one open
c
Opens sections from the last one open
B
Closes the sections from the last closed
d
Closes the sections from the last closed
The valves can be opened and closed from the right to the left and vice versa with the section control switches.
Prolonged pressure opens / closes the sections of half boom.
Examples:
• Closing of one section
• Opening of one section
• Simultaneous closing of half boom sections
• Simultaneous opening of half boom sections
12.4
Operating switches for hydraulic valves
Boom
release
Boom
locking
Boom
clockwise
leveling
Boom
counter-clockwise
leveling
Boom
height
increase
Boom height
decrease
Boom section
movement:
opening
Boom section
movement: closing
USE
As in the example here, shift
once the switch to the left to close
the first open section.
Shift several times to close sections
in sequence.
As in the example here, keep
the switch shifted to the left to close
the boom open half.
As in the example here keep the
switch shifted to the right to open the
boom closed half.
In the example here, shift
once the switch to the right to
open the first closed section.
Shift several times to open sections in
sequence.