1.
MACHINE NOT IN LEVEL OPERATING POSITION
•
Ensure that the Aqua Phase unit is level
2.
PRIMARY OR SECONDARY FILTER SCREEN(S) NOT CLEAN
•
Clean Filter Screen(s) located in the bottom of the wash reservoir inside the Wash
Chamber
3.
HIGH-LEVEL FLOAT SWITCH COVERED WITH DEBRIS
•
Unplug the Aqua Phase from the power supply
•
Locate the High-level float switch in the Water Reservoir inside the Wash Chamber.
•
Inspect for debris covering the probe
•
Remove debris, if present
4.
PUMP IMPELLER CLOGGED WITH DEBRIS
•
See “Pump Impeller Inspection Procedures” in this Aqua Phase Operating Manual. It is
recommended
that you contact the factory before you attempt to clear debris from the pump
impeller.
5.
CHEMICAL INJECTOR HOSE OR FITINGS ARE CRACKED OR LOOSE
•
Inspect Chemical Hoses and fittings for cracks and if loose.
•
Replace if damaged. You may order replacement parts by calling your dealer or the factory
6.
CHEMICAL PUMP HOSE CRACKED
•
Inspect hoses located inside the chemical pumps for cracks.
•
Replace if damaged.
You may order replacement parts by calling your dealer or the
factory
7.
FOAM IN WATER RESERVOIR AREA
•
Caused by something on the item washed
or by
the use of a foaming detergent or rinse-aid.
Foam may
affect certain sensors that control the filling and draining of water.
o
Press the “
Stop”
button and wait a few minutes until the foam dissipates.
o
Remove the hose from all cleaning supply bottles in the Aqua Phase Chemical
Cabinet.
o
Press
“Start”
Button and allow the Aqua Phase to do a complete cycle.
o
Repeat these steps until Aqua Phase starts draining normally.
Possible Causes/Solutions:
The “growling” noise is caused by air getting into the pump impeller. Growling noise is normally
heard at the end of the drain cycle. If you hear it continually, you have
may
one of the following
problems.
"GROWLING" NOISE
(pump cavitation)
LOW S
PRAY
VOLUME
Aqua Phase
, A Division Mid-State Stainless Inc. ●
330
W.
Benson Ave. ●
PO Box 228 ●
Grantsburg, WI 54840 ●
USA
800-208-9274 ●
715-463-5851
●
FAX: 715-463-5853
● Email: [email protected] ●
Summary of Contents for AQ-F250
Page 2: ......