DE
-
LIMING INSTRUCTIONS
(continued)
Aqua Phase
, A Division Mid-State Stainless Inc. ● 330 W. Benson Ave. ● PO Box 228 ● Grantsburg, WI 54840 ● USA
800-208-9274 ● 715-463-5851 ● FAX: 715-463-5853 ● Email: [email protected] ● WEB: www.aqua-phase.com
11.
(continued)
The de-liming solution will normally create foam inside the Wash Chamber.
The foam may
affect certain sensors that control the filling and draining of water.
If
Aqua Phase
does not stop draining after a few minutes, perform the following:
a)
Press the “STOP” button and wait a few minutes until the foam dissipates.
b)
Press the “START” button and allow Aqua Phase to do a complete cycle.
c)
Repeat the preceding Steps a) and b) until Aqua Phase starts draining normally.
d)
Return to Step 11 above.
12.
Press the “START” button and allow Aqua Phase to run another complete cycle.
13.
Examine and clean the Reservoir Filter Screens.
•
Repeat steps 10 – 13 until the filter(s) collect minimal debris.
•
You may select “
3 minutes
” or the shortest time cycle available when repeating Steps
10 – 13.
14.
Examine and clean the reservoir filter located inside the wash chamber reservoir.
15.
Drain Aqua Phase.
16.
Disconnect Aqua Phase from power source.
17.
Shut-off the water supply to Aqua Phase.
18.
CHECK FOR DEBRIS IN THE SPRAY NOZZLES
If your unit does not have the reservoir filter screens seated properly in place at all times,
expect most of the spray nozzles to become clogged during the de-liming of the
Aqua Phase.
After completing the de-liming processes above, check the spray nozzles to make certain
they
are not clogged.