Possible Causes/Solutions:
1.
NO MESSAGE ON LCD DISPLAY SCREEN.
•
A
qua Phase
not plugged in
•
GFCI not reset in power cord
•
Circuit breaker tripped
•
Blown fuse in A
qua Phase
Control
Panel
Assembly
2.
GFCI WILL NOT RESET.
•
Circuit breaker tripped.
•
Power outage to the area of the building.
•
Defective GFCI
•
Short in
Aqua Phase
system and GFCI doing its job.
3.
1 & 2 ARE OK
The
n check
:
•
Front door open
•
Front door out of adjustment/not contacting Front Door
Safety
Switch
•
Blown fuse in Control Panel Assembly
•
Defective Front Door Safety Switch
•
Defective Start Button
AQUA PHASE
W
ILL NOT START
Summary of Contents for AQ-F250